Zts-110 z-thermostat user manual printed in china f820-8031-0003 2/11/14 39 revised on 2/13/14 revised on 2/14/14 v3.05 fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) thi...
Table of contents introduction 2 features list 3 glossary 4 physical installation and wiring 5 installation location 6 6 wiring 7 jumper settings for electh-hpump and he-hg 9 10 10 10 11 11 12 17 18 18 20 23 23 25 26 26 check flirs / always listening mode in zts-110 28 28 36 37 38 39 39 physically i...
Features list hvac system type compatible: - standard (gas/electric) or heat pump multistage system compatible: - standard hvac systems: 2 stage heating, 1 stage cooling - heat pump systems: 2 stage heating, 1 stage cooling heat pump change over valve: - selectable change over with cool or with heat...
Physical installation and wiring read following scenarios carefully before you start as it matters to the battery life under z-wave operation: zts-110 can be powered by 4 x aa batteries, and/or 24vac c wire. A) if it is powered by batteries or powered by batteries first then applied with 24vac befor...
Figure 5. Heat pump hvac system wiring figure 6. Non-heat pump 2-wires system wiring figure 7.Heat pump 2-wires system wiring thermostat should be powered by batteries and support heating control only. Thermostat should be powered by batteries and support heating control only. For heat pump output, ...
9 10 jumper settings for electh-hpump and he-hg there are 6 jumpered pins on the thermostat circuit board that identify whether your system is: - gas or electric heater - non-heat pump or heat pump system you must ensure that these pins are set correctly for your system. The pin location is shown in...
11 12 activate/deactivate easy mode the zts-110 is default with easy mode, below illustrates the functions of easy mode: - active functions: change mode, change fan mode and temperature scale selection - inactive functions: scheduling, program mode, clock display, setting time, setting swing, settin...
13 14 if you deactivated the easy mode, you can continue to set up day, clock, 12/24 hour, f/c, swing and differential. Refer to below for steps: lcd indication step procedure / description press and hold "mode" key for 2 seconds to entry the setting mode. It will display "easy yes" if it stays in e...
15 16 note: explanations of swing and differential set point heat mode: thermostat controls the temperature according to the following diagram o o o example for heating: (set point = 70 f, swing = 1 f, differential = 2 f) o o => 1st stage heater turns on when room temp is 69 f and off at 71 f. O o =...
Change mode note: in heat mode =>it displays "heat" if electh is selected during jumper setting. => it displays "heat pump" if hpump is selected during jumper setting. Below example is based on heat pump lcd indication procedure / description press "mode" key once to change the operation mode: off -...
Override/permanent override note: override/permanent override is only available in heat, cool or auto mode. Lcd indication step procedure / description press "prog" key once to select prog mode: override or permanent override at home page. 1 press up/down key to adjust set point temperature in heat ...
Lcd indication step procedure / description press and hold "up" and "down" key for 2 seconds to disable / enable event during the time setting. If the event is disabled, "off" will be displayed. If the event is enabled, time will be displayed and hour will keep flashing. 5 wake mo tu we th fr wake a...
Battery low indication defrost indication out of temperature range indication 23 24 lcd indication procedure / description zts-110 thermostat will detect the battery level every 30 minutes; battery low icon will be displayed at home page if the battery is running out. (user is required to change new...
25 26 filter counter short cycle start up protection to protect the compressor / heat pump, those outputs forced off until 3minutes count down finished. Those outputs can be activated according to the room temperature after 3 minutes. Press and hold "mode" key to set the alert time for the filter us...
Check flirs / always listening mode in zts-110 z-wave add (include) / delete (exclude) into/from z-wave network add (include) zts-110 to gateway / controller z-wave network note: after z-wave inclusion process, if you reset zts-110 to default while both 24vac and batteries are applied, zts-110 will ...
Note: - it is recommended to perform the delete/exclude procedure before doing add/include. This is to make sure the zts-110 is not in any other z-wave network which will result in failure in inclusion process. - if the inclusion is failed, try exclusion, and/or reset zts-110 to factory default and ...
31 32 z-wave configuration parameters different user has different preferred settings of their thermostat, you may use the below configuration parameters to change settings of corresponding functionality. 500 (0x01f4) to 4000 (0x0fa0) hours default = 500 (0x01f4) hours resolution = 100 (0x0064) hour...
Parameter value range parameter no. Functions 0 (0x00) = disable auto report if room temperature is different from last report. Auto report if room temperature is different from last report. Delta change is >= o o 1 (0x01) = 1 f (0.5 c) o o 2 (0x02) = 2 f (1.0 c) o o 3 (0x03) = 3 f (1.5 c) o o 4 (0x...
Reset zts-110 to factory default settings lcd indication step procedure / description press and hold "fan" + "mode" keys for 2 seconds to entry the reset mode. Press up/down key to toggle yes/no selection. 1 press "prog" key once to confirm the action. => it will perform the reset if select "yes" or...
37 38 technical specifications model no. Bw8031us (zts-110us) bw8031au (zts-110au) bw8031eu (zts-110eu) rf frequency 908.4mhz (us) (zts-110us) 921.4mhz (au) (zts-110au) 868.4mhz (eu) (zts-110eu) rf operating distance up to 100ft outdoor line of sight, in unobstructed environment z-wave association g...