Heat input
Triple Crown burner:
4.0 kW
Semi-rapid burner:
2.0 kW
Auxiliary burner:
1.0 kW
TOTAL POWER:
G20 (2H) 20 mbar = 9 kW
G30 (3+) 28-30 mbar =
654 g/h
G31 (3+) 37 mbar = 643
g/h
Electric supply:
230 V ~ 50 Hz
3 core flexible cable with
non rewireable plug fitted
with a 3 amp cartridge
fuse
Gas connection:
G 1/2 "
Category:
II2H3+
Gas supply:
G20 (2H) 20 mbar
Appliance class:
3
By-pass diameters
Burner
Ø By-pass in 1/100 mm
Auxiliary
28
Semi-rapid
32
Triple Crown
56
Gas burners
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3+)
28-30/37 mbar
kW
kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30
28–30
mbar
G31
37 mbar
g/h
g/h
Auxiliary
1.0
0.33
70
0.095
50
73
71
Semi-rapid
2.0
0.45
96
0.190
71
145
143
Triple
Crown
4.0
1.4
146
0.381
98
291
286
Environment concerns
The symbol on the product or on its packaging
indicates that this product may not be treated as
household waste. Instead it should be taken to the
appropriate collection point for the recycling of electrical
and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential
negative consequences for the environment and human
health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed
information about recycling of this product, please contact
your local council, your household waste disposal service
or the shop where you purchased the product.
Packaging material
The packaging materials are friendly to the environ-
ment and can be recycled. The plastic components
are identified by marking: >PE<,>PS<, etc. Discard the
packaging materials as household waste at the waste dis-
posal facilities in your municipality.
12
www.zanussi.com