Zelmer 619.5 Service Manual - page 22
22
- Undo the four screws 72, which connect left catch 7 and right catch 8 with the upper cover
9; unfold catches 7, 8and remove the upper cover 62 with cover catch 60 and spring 68.
- Undo the four screws 72, which secure the side strip 6; lift up the side strip and, without
detaching the pipe 36 from the inlet stub pipe 4 put it next to the base 43.
- Pull the plug of the power cord through the opening located in the pocket 26; remove the
pocket 26.
- Open the outlet cover 40 and pull it out with the exhaust air filter 18; without disconnecting
electrical wires gently remove the entire set (i.e. upper cover 9, bottom cover 16, suction
unit 12) with base fins 43; place it on the base and disconnect electrical wires from ring
contacts of the cord rewinder 23.
- Disconnect electrical wires from contacts of the cord rewinder and remove the cord
rewinder 23 from the base grooves 43.
- Unwind the power cord 24 wound on the spool, unfold catches of the labyrinth and push it
out of the spool; disconnect the power cord 24 from U contactsand pull it out of the
labyrinth of.
Removing the suction unit
- Release the cover catch switch 60, lift the upper cover 62, remove the front container 52
and rear container 2.
- Undo the four screws 71 in the upper cover 62 and remove the handle 53.
- Detach the cover 59 from the upper cover 62 by disconnecting the wiring harness of the
electrical wires from the switches 55 and 57, tighten the catches of the flexy tube grommet
10 and push it through the opening in the upper cover 62.
- Undo the four screws 72, unfold catch 7, 8 and remove the upper cover 62; with the cover
catch 60, and spring 68.
- Undo the four screws 68, which secure the side strip 6; lift up the side strip and, without
detaching the pipe 36 from the inlet stub pipe 4, put it next to the base 43.
- Undo the four screws 72, which connect the upper cover 9 with the bottom cover 16.
Remove the upper cover 9, upper gasket 11 and suction unit 12.
- Disconnect electrical wires from the suction unit.
Removing the pump
- Undo the four screws 72, which secure the side strip 6, remove the side strip 6 from the
base 43 and detach the pipe 36 from the inlet stub pipe 4.
- Lift up the suction unit (built-in) and remove: Pump cover 35, pump 32.
- From the pump, remove: Set of pump wires 29, fuse 27.
- Remove: elbow-pipette 33 with pipe 36, elbow 30 with the pipe and clamp band 69 and
shock absorber 31.