2gig Technologies Go!Control Panel User Manual - page 41
Go!Control Wireless Security System | User Guide
40
©2013 2GIG Technologies Inc. All Rights Reserved.
Key Fob Options
The installer selects which options are
enabled for each key fob (1‐8) used with the
system. Refer to the table below for the
options selected for your key fobs:
Key Fob Arming Bypass Options
Options
All Key Pads
Auto‐bypass all open perimeter
sensors and un‐bypass a sensor if
closed while the system is armed
Auto‐bypass open perimeter sensors
permanently while armed
Allow key fob arming only when all
perimeter sensors are closed
Wireless Keypad Emergency
Keys
Each standard wireless keypad has Fire and
Police emergency buttons that can be
enabled or disabled for each keypad. Refer
to the table below for options set for your
keypads:
Exit Delay Restart
The Exit Delay Restart option will extend the
Exit Delay one time if you need to re‐enter
the premises. When the system is armed in
the Away Mode or Stay Mode, the Exit Delay
gives you time to leave without setting off
the alarm. With the Exit Delay Restart
option, re‐entering the premises after you
have left, but before the Exit Delay timer
expires, will restart the Exit Delay timer,
giving you the full length of time to leave
again. The restart option only works once,
each time the system is armed.
•
On
•
Off
Cancel Display
A “cancel” message will be sent to the
Central Station if the system is disarmed
within a preset period of time after an alarm
is triggered. The system can be set to display
that a cancel report was sent, or for higher
security, the system can be set not to display
the cancel message.
•
On
•
Off
Cancel Time
To limit responses to false alarms, a “cancel”
message will be sent to the Central Station if
the system is disarmed within a preset
period of time after an alarm is triggered.
The alarm report is always sent, but it will be
followed by a cancel report if you disarm the
system within the preset time.
This option helps the Central Station to
determine whether you accidently caused
the alarm or if the alarm report was caused
by an intruder. It also lets the Central Station
know that you have returned to the
premises. Even if a cancel message is sent,
the Central Station will verify the alarm and
possibly dispatch help. The cancel message
may be processed by the Central Station at a
later time depending on system
programming.
•
5 Minutes is the default, or _______
Minutes
Dialer Delay
If an alarm occurs, the system will delay
dialing for a short time to allow you to
disarm the system in case the alarm was
accidentally tripped. The dialer delay
reduces nuisance traffic to the Central
Station and can prevent receiving fines that
Options
1 2 3 4 5 6 7 8
Arm without Exit Delay
Allow key fob disarming
Enable key fob auxiliary key
Options
1 2 3 4 5 6 7 8
Auxiliary Alarm
Audible Alarm
Silent Panic Alarm
Fire Alarm
Emergency Keys Disabled
Option
1 2 3 4
Emergency Keys Enabled
Emergency Keys Disabled