2gig Technologies Go Control Install Manual - page 25
24
©2013 2GIG Technologies Inc. All Rights Reserved.
PROGRAMMING QUESTION TABLE
Q# Question
Default
Q‐1
Select RF sensor # (01‐48)
Select RF sensor (#) type
(00) unused
Select RF sensor (#) equipment type
Varies by RF sensor type
(only shown for some
sensor types)
Select RF sensor (#) equipment code
(0000) other
Enter RF sensor (#) other equipment code
(0‐9999)
0‐Only shown if other is
selected
Enter RF sensor (#) serial number (7 digits)
0000000
Select RF sensor (#) equipment age (0‐1)
(0) new
Select RF sensor (#) loop number (1‐3)
Varies with sensor model
selected
Select RF sensor (#) dialer delay (0‐1) ‡
(1) enabled‐except for fire
and CO
Construct RF sensor (#) voice descriptor
No default
Select RF sensor (#) reports (0‐1)
(1) enabled
Select RF sensor (#) supervised (0‐1)
(1) enabled
Select RF sensor (# chime (0‐5)
(0) disabled
Q‐2
Select wired sensor # (1‐2)
Select wired sensor (#) type
(00) unused
Select wired sensor (#) equipment type
Varies by wired sensor type
(only shown for some
sensor types)
Enter wired sensor (#) equipment code (0‐9999)
0
Select wired sensor (#) equipment age (0‐1)
(0) new
Select wired sensor (#) normal state
(0) not used
Select wired sensor (#) dialer delay ‡
(1) enabled
Construct wired sensor (#) voice descriptor (0‐1) ‡
No default
Select wired sensor (#) reports (0‐1)
(1) enabled
Select wired sensor (#) chime (0‐5)
(0) disabled
Q‐3
Select fob # (1‐8)
Select fob (#) used (0‐1)
(0) unused
Select fob (#) equipment code (0000)
(0000) other
Enter fob (#) other equipment code
(0‐9999)
0‐Only shown if other is
selected
Enter fob (#) serial number (7 digits)
0000000
Select fob (#) equipment age (0‐1)
(0) new
Select fob (#) emergency key (0‐4)
(0) disabled
Select fob (#) key 2 can disarm (0‐1)
(1) enabled
Construct fob (#) voice descriptor
keyfob #
Select fob (#) arm no delay (0‐1)
(0) disabled
Select fob (#) key 4 output (0‐2)
(0) disabled
Q‐4
Select RF keypad # (1‐4)
Select RF keypad (#) used (0‐1)
(0) unused
Select RF keypad (#) equipment code
(0000) other
Enter RF keypad (#) other equipment code
(0‐9999)
0‐Only shown if other is
selected
Enter RF keypad (#) serial number (7 digits)
0000000
Select RF keypad (#) emergency age (01)
(0) new
Select RF keypad (#) emergency keys (01)
(1) enabled
Construct RF keypad (#) voice descriptor
keypad #
Q5
Enter exit delay, in seconds (45‐120)
‡
60 seconds
Q6
Enter entry delay 1, in seconds (30‐240) ‡
30 seconds
Q7
Enter entry delay 2, in seconds (30‐240)
‡
45 seconds
Q8
Select dialer (0‐1)
(0) disabled
Q9
Enter dialing prefix (0‐4 digits)
No default
Q10 Enter call wai ng disable code (0‐6 digits) ‡
No default
Q11 Enter CS #1 phone number (0‐25 digits)
No default
Q12 Enter CS #1 account number (4 digits)
No default
Q13 Select 2‐way voice (0‐2)
(1) stay online
Q14 Select silent panic/burglary listen only (0‐1)
(1) enabled
Q15 Select dialing type (0‐1)
(0) touch tone
Q16 Select police emergency key (0‐2)
(1) audible
Q17 Select fire emergency (0‐1)
(1) audible
Q18 Select emergency key (0‐1)
(1) audible
Q19 Select quick arming (0‐1)
(1) enabled
Q20 Select swinger shutdown count (1‐6) ‡
(2) two trips
Q21 Select siren supervision time (0‐3)
(0) disabled
Q22 Enter CS lack of usage notification time 0‐255
7 Days
Q23 Enter radio modem network failure time 0‐255
30 minutes
Q24 Select radio network failure causes trouble 0‐1
(1) enabled
Q25 Select radio modem network failure reports 0‐1
(1) enabled
Q26 Select auto stay (0‐1)
(1) enabled
Q27 Select exit delay restart (0‐1)
(1) enabled
Q28 Select quick exit (0‐1)
(1) enabled
Q29 Enter periodic test, in days (0‐255)
30 days
Q31 Enter cancel me, in minutes (5‐255) ‡
5 minutes
Q32 Select cancel display (0‐1) ‡
(1) enabled
Q33 Select cross sensor 47‐48 (0‐1)
(0) disabled
Q34 Enter cross sensor timeout in seconds (10‐120)
10 seconds
Q35 Select abort window dialer delay (0‐2)
(1) 30 seconds
Q36 Select burglary bell cutoff (0‐4)
(0) 4 minutes
Q37 Select fire bell cutoff (0‐4)
(0) 4 minutes
Q38 Enter time to detect AC loss report time (0‐30)
0 minutes
Q39 Select random AC loss report time (0‐1)
(1) enabled
Q40 Enter CS #2 phone number (0‐25 digits)
No default
Q41 Enter CS #2 account number (4 digits)
No default
Q42 Select remote control phone (0‐3)
(3) data and voice
Q43 Enter installer code (4 digits)
1561
Q44 Select lock installer programming (0‐2)
(0) disabled
Q45 Select lock default programming (0‐2)
(0) default all
Q46 Select trouble reports to CS (0‐1) *
(1) enabled
Q47 Select trouble resound after holdoff (0‐7)
(0) disabled
Q48 Enter download csid (6 digits)
000000
Q49 Select programming mode entry reports to CS (0‐1)
(0) disabled
Q50 Select trouble reports to CS (0‐1)
(1) enabled
Q51 Select manual bypass reports to CS (0‐1)
(0) disabled
Q52 Select AC loss reports to CS (0‐1)
(1) enabled
Q53 Select system low battery reports to CS (0‐1)
(1) enabled
Q54 Select RF low battery reports to CS (0‐1)
(1) enabled
Q55 Select opening reports to CS (0‐1)
(0) disabled
Q56 Select closing reports to CS (0‐1)
(0) disabled
Q57 Select alarm restore reports to CS (0‐1)
(0) disabled
Q58 Select trouble restore reports to CS (0‐1)
(1) enabled
Q59 Select bypass restore reports to CS (0‐1)
(0) disabled
Q60 Select AC restore reports to CS (0‐1)
(1) enabled
Q61 Select system low batter restores report to CS (0‐1)
(1) enabled
Q62 Select RF low battery restores reports to CS (0‐1)
(1) enabled
Q63 Select phone fail detect (0‐1)
(0) disabled
Q64 Select smart test reports (0‐1)
(0) disabled
Q65 Select RF jam causes trouble (0‐1)
(0) disabled
Q66 Select daylight saving (0‐1)
(1) enabled
Q67 Select daylight saving start month (01‐ 12)
(03) March
Q68 Select daylight saving start Sunday (1‐7)
(1) 2nd
Q69 Select daylight saving end month (01‐12)
(11) November
Q70 Select daylight saving end sunday (1‐7)
(1) 1st
Q71 Select system tamper causes trouble (0‐1)
(1) enabled
Q72 Select quick bypass (0‐1)
(0) disabled
Q73 Select disarming keyfob after alarm alert (0‐1)
(0) disabled
Q74 Select keyfob arm/disarm confirmation (0‐1)
(0) disabled
Q75 Select auto unbypass for manual bypass (0‐1)
(1) enabled
Q76 Select force bypass reports (0‐1)
(0) disabled
Q77 Select event log (0‐3)
(3) all events
Q78 Select output (00‐10)
11 follows internal
sounder alarm
Q79 Select Z‐Wave feature (0‐3)
(1) disabled by visible
Q80 Select Z‐Wave switches feature (0‐1)
(0) disabled
Q81 Select Z‐Wave thermostats feature (0‐1)
(0) disabled
Q82 Select Z‐Wave switches feature (0‐1)
(0) disabled
Q83 Select temperature display units (0‐1)
(0) degrees Fahrenheit
Q84 Select services require master code
(0) disabled
Q85 Select master user access to z
(0) disabled
Q86 Select disable siren after two‐way audio (0‐1)
(0) disabled
Q87 Select keyfob/remote arming mode on system not
ready (0‐2)
(0) auto‐bypass with zone
participation on restore
Q88 Select siren mode (0‐1)
(0) sound for burglary and
Fire/CO
Q89 Select allow backlight always on (demo mode)
(0) disabled
Q90 Select energy feature
(1) enabled
Q91 Select radio modem supplier
(0‐2) depends on supplier
‡ Default set for SIA CP‐01 compliance
* For UL985 Installations, this feature must be disabled