Q-78 Select output (00-10)
DEFAULT: Follows internal sounder
alarm (11) (Required SIA CP-01 Default)
The system’s open collector output is available on
the Control Panel’s terminal block to connect to an
external device. The conditions that will cause the
open collector output to activate are
programmable.
•
Select one activation option for the Control
Panel’s open collector output:
(00) disabled
(01) activated when armed
(02) activated when disarmed
(03) activated on FTC (failure to communicate)
(04) activated on siren supervision
(05) activated on radio fault
(06) activated on burglary alarm
(07) activated on fire alarm
(08) activated on any alarm
(09) activated on any system trouble
(10) Z‐wave activation (Option #10 not currently
active)
(11) follows internal sounder alarm
(12) follows exit/entry beeps
Q-79 Select Z-Wave feature (0-3)
DEFAULT: Disabled but visible (1)
The Z‐Wave home services feature can be enabled
or disabled with various remote control access
options.
•
The default (1) displays the Services button,
but will show a message that the feature is
currently disabled and the user should call the
installer.
•
To hide the Services button, select disabled
and hidden (0).
•
To show the Services button and disable off‐
site remote control, select (2).
•
To show the Services button, with Z‐Wave
rules disabled and off‐site remote control
enabled, select (3).
Q-80 Select Z-Wave switches
feature (0-1)
DEFAULT: Disabled (0)
Display of the Home Service’s Switches button can
be enabled or disabled.
NOTE:
This programming question only
functions if the Z‐Wave feature enable
question Q‐79 is set to (2) or (3).
•
The default (0) hides the Switches button.
•
To display the Switches button, select enabled
(1).
Q-81 Select Z-Wave thermostats
feature (0-1)
DEFAULT: Disabled (0)
Display of the Home Service’s Thermostats button
can be enabled or disabled.
This programming question only functions if the Z‐
Wave feature enable question Q‐79 is set to (2) or
(3).
•
The default (0) hides the Thermostats button.
•
To display the Thermostats button, select
enabled (1).
Q-82 Select Z-Wave door locks
feature (0-1)
DEFAULT: Disabled (0)
Display of the Home Service’s Doorlocks button can
be enabled or disabled. This programming question
only functions if the Z‐Wave feature enable
question Q‐79 is set to (2) or (3).
•
The default (0) hides the Doorlocks button.
•
To display the Doorlocks button, select
enabled (1).
Q-83 Select temperature display
units (0-1)
DEFAULT: Degrees Fahrenheit (0)
The Home Service’s Z‐Wave thermostat display
screens can show the temperature in degrees
Fahrenheit or degrees Celsius.
NOTE:
This programming question only
functions if the Z‐Wave feature enable
question Q‐79 is set to (2) or (3) and the
thermostat feature is enabled with Q‐81.
•
The default (0) displays temperature in
degrees Fahrenheit.
•
To display temperature in degrees Celsius,
select (1).
Open Collector Output Mode