3M 724 Instructions Manual - Section 4.
12
Section 4.
Selection of Test Voltage
and Resistance Limit
Tools required - Small blade,
screwdriver.
The Model 724 monitor allows for the
selection of test voltages (9v or 16v)
and resistance limits (10 Megohms or
35 Megohms). The additional ranges
have been added to accommodate
global ESD requirements. Selection of
the operating parameters are left up to
the user’s discretion.
a) Select the desired resistance and
voltage limit by moving the
appropriate slide switch (with
screwdriver) on the side of the
Model 724 monitor to the desired
position (Fig. 2).
Section 5.
Mounting the 3M
™
Model 724
Monitor and 3M
™
Model 732
Remote
a) Mount or position the Model 724
monitor so that the lamps are easily
viewed by the operator (Figs. 10 and
11). Mount the Model 724 monitor
to the underside of a work bench top
or shelf through the two holes
located at the top rear of the case
using the two screws supplied. If
using the screws is not possible,
apply an appropriate amount of
durable, double-sided adhesive
foam tape to the case.
b) Locate the Model 732 Dual
Conductor Remote Input Jack so
that it is convenient for the
operators to attach their wrist strap
ground cord. Mount the remote
with the screws provided.
Fig. 10 - Model 724 mounted on bench top.
Fig. 11 - Model 724 mounted under shelf or bench.