n) Test as in step (6l) above. However,
set the resistance as follows and
observe the 724 Monitor output:
1.3 Megohms - Yellow low lamp
(L) flashing, green (OK) lamp (1)
ON, and audible alarm OFF.
1.7 Megohms - Yellow low lamp
(L) OFF, green (OK) lamp (1) ON,
and audible alarm OFF.
29.8 Megohms - High red wrist
strap lamp (H) OFF, green (OK)
lamp (1) ON, and audible alarm
OFF.
40.2 Megohms - High red wrist
strap lamp (H) ON, audible alarm
ON (continuous tone), and green
(OK) lamp (1) OFF.
o) Repeat step (6n) for input #2 of the
Model 732 Dual Conductor
Remote Input Jack. Audible alarm
will be fast chirping beep.
Section 12.
Specifications
724 Monitor Size:
6.5 x 3.125 x 1.375 in.
(16,5 x 7,9 x 3,5 cm)
732/733 Remote Input Jack Size:
2.75 x 1.0 x 1.0 in.
(7,0 x 2,5 x 2,5 cm)
Power Supply Requirements:
Input: 120 Vac +/-10%
(North America)
Output: 25 Vdc @ 50 mA
rated load
Output Plug Polarization:
Center Negative
Output Plug Dimensions: 5,5mm O.D.
x 2,1mm I.D. x 9,5mm Length
Accuracy: +/-15%
Test Voltage: 9 VDC / 16 VDC
Open circuit
Test Current: Less than 3 microamps
Environmental Operating Conditions:
Temperature:
Maximum 110°F / 43°C
Minimum 50°F / 10°C
Humidity:
Maximum 75% R.H.
Section 13.
Parts Included
1 ea. Model 724 Work Station
Monitor
1 ea. Model 732 Dual Conductor
Remote Input Jack
1 ea. AC Adapter (North America
Only for outside North America
see Power Supply
Requirements (Section 12)
1 ea. 724 Ground Cord
1 ea. 2380 Monitor/Table Mat Cord
1 ea. Two-Wire Connector
4 ea. Mounting Screws
2 ea. Wire Management Clips
1 ea. User Instruction Manual