c) Plug the AC
adapter into a
3-prong grounded
outlet (North
American System).
Outside North
America use
appropriate AC
adapter (see
specifications
Section 11). The
724 monitor is
ready for use.
Section 6.
Wrist Strap Connection
a) Attach a 3M Dual Conductor
Ground Cord to a 3M Dual
Conductor Wrist Band (Fig.13).
Plug the cord into either of the two
jacks on the Model 732 Dual
Conductor Remote Input Jack
(Fig.14). Plugging into a jack
activates the monitor for that input.
b.) The high wrist strap red lamp
(H) should illuminate and the
corresponding audible alarm for
the input (1 or 2) should sound
indicating proper functioning of
the monitor.
c.) Slip the wrist band on your
wrist. The alarm should quiet
and the wrist strap high red lamp
(H) should slowly extinguish.
The corresponding OK wrist
strap green lamp (1 or 2)
should illuminate.
732 Remote
Ground
When not using work station
monitoring feature,connect
work surface wire to ground.
Conductive
Work Surface
Ground
AC
Adaptor
Rear
Ground
722 Monitor
Fig. 13 - Connecting ground cord to wrist band.
Fig. 14 - Connecting wrist snap ground cord to
Model 732.
Fig. 12 - Model 724 wire connection diagram for single
work station.
Ground
Rear
Ground
Ground
AC Adapter
732 Remote
732 Monitor
Conductive
Work Surface
When not using work
station monitoring
feature, connect
work surface wire