3onedata IES7110-2GS-P User manual - page 2
IES7110-2GS-P (12/48VDC)
1. Ground screw
2. PWR1/PWR2 power input
3. Relay output terminal block
4. DIP switch
5. CONSOLE port
6. DIN-Rail mounts
7. Wall mount screw hole
8. Relay alarm LED
9. The power LED
10. Systems running LED
11. 100M Link/ACT LED
12. 1000M Link/ACT LED
13. 1000Base-FX SFP port
14. 10Base-T /100Base-TX port
IES7110-2GS-P(110/220VAC)
1. Ground screw
2. Power input (L/-, FG, N/+)
3. Relay output terminal block
4. DIP switch
5. CONSOLE port
6. DIN-Rail mounts
7. Wall mount screw hole
8. Relay alarm LED
9. Systems running LED
10. 100M Link/ACT LED
11. 1000M Link/ACT LED
12. 1000Base-FX SFP port
13. 10Base-T /100Base-TX port
Note: AC power supply input did not have power supply
indicator
IES7110-2GS-2F-P (12/48VDC)
1. Ground screw
2. PWR1/PWR2 power input
3. Relay output terminal block
4. DIP switch
5. CONSOLE port
6. DIN-Rail mounts
7. Wall mount screw hole
8. Relay alarm LED
9. The power LED
10. Systems running LED
11. 100M Link/ACT LED
12. 1000M Link/ACT LED
13. 1000Base-FX SFP port
14. 10Base-T /100Base-TX port
15. 100Base-FX port
IES7110-2GS-4F-P (12/48VDC)
1. Ground screw
2. PWR1/PWR2 power input
3. Relay output terminal block
4. DIP switch
5. CONSOLE port
6. DIN-Rail mounts
7. Wall mount screw hole
8. Relay alarm LED
9. The power LED
10. Systems running LED
11. 100M Link/ACT LED
12. 1000M Link/ACT LED
13. 1000Base-FX SFP port
14. 10Base-T /100Base-TX port
15. 100Base-FX port
【
Appearance and dimension】
Unit(mm)
【
Power supply input】
DC
AC
Top view
Front view
IES7110-2GS series top panel provided 4 bit power supply
input terminal block, support AC or DC input. DC power supply
input supported redundancy function, provided PWR1 and PWR2
power input, can use for single, and can connect 2 separately
power supply system, use 1 pair terminal block connect the device
at the same time. If one of the power system broke, the device can
work un-interruptible. Built-in overcorrect protection, Reverse
connection protection. Voltage input range is 12 ~ 48VDC
(
terminal block defined as: V1-、V1+、V2-、V2+).
AC voltage input range: 110~220VAC ( 47 ~ 63Hz ) , the
defined of terminal block: N/-, FG, L/+.