NO (normal open) connected with COMMON. The number of DO dependents on the
server type.
parameter Value
description
H – NC connected with COMMON
do
L – NO connected with COMMON
return
Redirect to the page
parameter is assigned. The
a full URL path or relative path according the the
current path. If you omit this parameter, it will
redirect to an empty page.
Example: Drive the digital output 1 to high and redirect to an empty page
http://myserver/cgi-bin/setdo.cgi?do1=H
Query Status of the Digital Input
Note: This request requires the privilege of I/O access control.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: image/jpeg\r\n
Content-Length:
\r\n
[di1=
[di2=
[di3=
[di4=