A&D Profibus Interface AD-4402 OP-22 Instruction Manual - page 16
Page 14
AD-4402 OP-22
5.3.4.
5.3.4.
5.3.4.
5.3.4.Write Command List
Write Command List
Write Command List
Write Command List
Command Name
Command No.
Output Data
Note
Material name 1 (1st to 4th character)
1
Material name 2 (5th to 8th character)
2
Material name 3 (9th to 12th character)
3
Characters
data #
Material hopper
5
Final
6
Free fall
7
Preliminary
8
Optional preliminary
9
Over
10
Under
11
Zero band
12
Full
13
Tare
14
Supplementary flow open timer
15
Supplementary flow close timer
16
AFFC range
17
Initial dribble supply
18
Initial medium supply
19
Numerical
data
This data is stored in
each material code.
Specify a material
code No. before the
input.
A material code No.
specified at "Material
code to store (33)" of
"Write command".
AFFC:Automatic free fall
compensation
Recall material code
32
Material code to store
33
Code No.
0 to 99
Recipe name 1 (1st to 4th character)
40
Recipe name 2 (5th to 8th character)
41
Recipe name 3 (9th to 12th character)
42
Characters
data #
Material 1
44
Material 2
45
Material 3
46
Material 4
47
Material 5
48
Material 6
49
Material 7
51
Material 8
50
Material 9
52
Material 10
53
Code No.
0 to 99
This data is stored in
each recipe codes.
Specify a recipe code
No. before the input.
Specify a recipe code
No. at "Recipe code
to store (57)" of
"Write command".
Use "Material 1" at
first and in order. Set
"FFFFFFFF" to
unused codes.
Recall recipe code
56
Recipe code to store
57
Code No.
0 to 99
# Use ASCII code for character data. If data is not used, fill with space codes (20h).
OUT DATA,
1st word and 2nd word
OUT DATA,
5th word