A-Neuvideo ANI-88HDRH Instruction manual - page 10
8
RS-232 & Telnet Commands
COMMAND
DESCRIPTION
DESCRIPTION OF PARAMETER
SET TELNET USERNAME S
Set Telnet username
s = name string
GET TELNET USERNAME
Print Telnet username to the screen NONE
GET TELNET USERNAME
Print Telnet username to the screen NONE
SET TELNET PASSWORD S
Set Telnet password
s = password string
GET TELNET PASSWORD
Print Telnet password to the screen
NONE
SET TELNET PORT N
Set Telnet port number
n = 23,… (Telnet port number)
GET TELNET PORT N
Set Telnet port number
{s} = password string
GET HOSTENAME N
Print Hostname to the screen
{s} = name string
SET WEBGUI LOGIN TIMEOUT N
Set WebGUI login timeout
n = 1,2,3,4…Seconds
ROSDINFO
Get OSD information status
NONE
USBPWR
USB Power ON/OFF
USBPWR P1 P2
P1 = Output Port (1~4) / P2 = Action (ON/OFF)
SET IN N NAME S
Name an input source
n = 1,2,3…8
GET IN N NAME
Print the input name to the screen
n = 1,2,3…8
SET OUT X NAME S
Name an output sync monitor
x = a,b,c…h / s = name string name / size: 32 Byte
GET OUT X NAME
Print the output name to the screen
x = a,b,c …h
SET OUT X ROUTE N
Set output routing
x = a,b,c,d,e…h / n = 1,2,3,4,5…8
GET IN NAME LIST
Print all input name to the screen
NONE
GET OUT NAME LIST
Print all output name to the screen
NONE
SET OUT X 4K2K DOWNSCALE MODE N Config output x 4K2K downscale
mode for sync monitor
x = a,b,c…h / n = 0-passthrough, 1-auto, 2-1080p
GET OUT X HDCP 4K2K DOWNSCALE
MODE N
Print output x 4K2K downscale
mode to the screen
x = a,b,c…h / n = 0-passthrough, 1-auto, 2-1080p
GET IN N1 HACTIVE N2
Print input H active to the screen
n1 = 1,2,3…8 / n2 = 640, 800, 1024
GET IN N1 VACTIVE N2
Print input V active to the screen
n1 = 1,2,3…8 / n2 = 480, 768, 600
GET IN N1 REFRESH RATE
Print input refresh rate to the screen n1 = 1,2,3…8 / n2 = 5994, 6000, 7500, 8503
GET IN N1 INTERLACE
Print input interlace to the screen
n1 = 1,2,3…8 / n2 = 0-none interlace, 1-interlace
GET IN N1 SYNC STATUS
Print input sync status to the screen n1 = 1,2,3…8 / n2 = 0-no sync, 1-sync active
GET IN N1 TIMING
Print input n Timing
n = 0,1,2,3,4,5…8
(0-native, 1-800x600, 2-1024x768,...)
SET IR IN CHANNEL N
Set IR in channel information
n = 0,1,2,3…15
GET IR IN CHANNEL N
Get IR in channel information
n = 0,1,2,3…15
SET IR IN CUSTOM CODE 0XH
Set IR in custom code
data: 0x0000~0x7fff
GET IR IN CUSTOM CODE
Get IR in custom code
data: 0x0000~0x7fff
SET FAN CONTROL MODEL N
Print fan speed
n: 0=always ON, 1=follow temperature
GET FAN CONTROL MODE
Print fan speed
n: 0=always ON, 1=follow temperature
GET FAN N1 SPEED
Print fan speed
n1 = 1,2 / n2 = 0,1,2,...
GET DEVICE TEMPERATURE N
Print machine temperature
n = 0,1,2,3…
A