A-Neuvideo ANI-88HDRH Instruction manual - page 12
10
RS-232 & Telnet Commands
COMMAND
DESCRIPTION
DESCRIPTION OF PARAMETER
GET OUT X BANNER FONT COLOR S
Query OSD text color
x = a,b,c…h / s = black, white, red, green, blue,
magenta, yellow, cyan, gray
GET OUT BANNER FONT COLOR LIST S Query OSD text color list value
s = black, white, red, green, blue, magenta,
yellow, cyan, gray
SET OUT X OSD BACKGROUND COLOR S
Change OSD text color
x = a,b,c…h / s = black, blue, green, cyan, red,
magenta, yellow, white…
GET OUT X OSD BACKGROUND COLOR S
Change OSD background color
x = a,b,c…h / s = black, blue, green, cyan, red,
magenta, yellow, white…
GET OUT OSD BACKGROUND COLOR
LIST S
Query OSD background color list
value
s = black, blue, green, cyan, red, magenta,
yellow, white…
SET IN N1 EDID N2
EDID TABLE SELECT
n1 = 1,2,3,4… 8
n2 = 1,2,3… 22 (1-INT1, 2-INT2…,7-USER1,
8-USESR2…,15-Sink A, 16-Sink B)
Total User EDID number equal to Input source
number.
Total Sink EDID number equal to output number
of device.
GET IN N1 EDID N2
Input EDID table query
n1 = 1,2,3,4… 8
n2 = 1,2,3… 22 (1-INT1, 2-INT2…,7-USER1,
8-USESR2…,15-Sink A, 16-Sink B)
Total User EDID number equal to Input source
number.
Total Sink EDID number equal to output number
of device.
GET IN EDID LIST NN
Input EDID table list query
nn = 1,2,3… 22 (1-INT1, 2-INT2…, 7-USER1,
8-USESR2…,15-Sink A, 16-Sink B)
Total User EDID number equal to Input source
number.
Total Sink EDID number equal to output number
of device.
SET EDID N NAME S
EDID TABLE SELECT
n = 7,8,9,…14 (only USER EDID name can be
edited) / s = string / name size: 32 Byte
GET EDID N NAME S
EDID TABLE SELECT
n = 7,8,9,…14 (only USER EDID name can be
edited) / s = string / name size: 32 Byte
SET USER N EDID DATA H,H,H……
Upload EDID
n = 1,2,3,4… 8 (1- USER1, 2-USER2…)
h = EDID data
GET USER N EDID DATA
Download User n EDID
n = 1,2,3,4…8 (1-INT1, 2-INT2…) / h = EDID data
GET SINK X EDID DATA
Download SINK [x] EDID
x = A,B,C…h / h = EDID data
GET IN N EDID DATA
Download Input n EDID
n = 1,2,3… 8
h = EDID data (1-INT1, 2-INT2…,7-USER1,
8-USESR2…, 15-Sink A, 16-Sink B)
Total User EDID number equal to Input source
number.
Total Sink EDID number equal to output
number of device.
GET ALL IN EDID LIST
Print EDID list
n1 = 1,2,3,4… 8
n2 = 1,2,3… 22 (1-INT1, 2-INT2…,7-USER1,
8-USESR2…, 15-Sink A, 16-Sink B)
Total User EDID number equal to Input source
number.
Total Sink EDID number equal to output number
of device.
GET INTERNAL N EDID DATA
Download EDID
n = 1,2,3,4…6 (1-INT1, 2- INT2…) / h = EDID data
SET ALL IN EDID MODE B
Set EDID mode to “all” or “appoint”
b = ON, OFF (all or appoint)
GET ALL IN EDID MODE B
Print EDID mode to “all” or “appoint” b = ON, OFF (all or appoint)