AAP Elite S series Operating Manual - Programming Summary Guide
28
PROGRAMMING SUMMARY GUIDE
The program addresses available to the owner in Client Program Mode
are listed below. “P” represents the
sents the
P1E 1-100E (User Codes 1-100)
P18E 21-100E (learn radio user 21-100)
P19E 21-100E (Delete radio user 21-100)
P20E 0E (Find a radio user location)
P21E 1-100E (learn access tag/card user 1-100)
P22E 1-100E (Delete access tag/card user 1-100)
P23E 0E (Find a radio user location)
P25E12E (Option “1” on hides the users codes from the Installer)
P26E1E HHMM (Real time clock hour and minutes)
P26E2E 1-7E (Real time clock day, 1 = Sunday to 7 = Saturday)
P26E3E DDMMYY (Real time clock Date/Month/Year)
P26E4E (Daylight saving active. If “1” is On daylight saving is active)
P27E1E 0-5E (Daylight saving start Sunday)
P27E2E 0-5E (Daylight saving end Sunday)
P28E1E 1-12E (Daylight saving start Month)
P28E2E 1-12E (Daylight saving end Month)
P29E1E 0-23E (Daylight saving start Hour)
P29E2E 0-23E (Daylight saving end Hour)
P63E 1-2E####E (Area A (1) or B ( 2) DTMF arm/disarm code, 1-4 digits)
P164E 1-16E (learn radio detector 1-16)
P165E 1-16E (Delete radio detector 1-16)
P166E 0E (Find a radio detector location)
P170E 1-8E DDMMYY (Program holiday 1-8, Date/Month/Year)
P175E12E ####E (DTMF output control code)
P175E13E ####E (DTMF microphone code)
P175E14E ####E (DTMF voice/domestic acknowledge code)
P175E15E ####E (DTMF force test call code)
P200E 6E (Start walk-test mode)
P E (Leave Client Program Mode)