ABB C1900 Series Installation Manual

Other manuals for C1900 Series: Operating Manual
Manual is about: Circular Chart Recorder/Controller

Summary of C1900 Series

  • Page 1

    Inform it circular chart recorder and recorder/controller c1900 series installation guide im/c1900–ins_10

  • Page 2

    Abb the company we are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of abb, a world leader in process automation technology, we offer customers applicati...

  • Page 3

    1 modbus (rtu) serial adaptors serial connections programming pages ascii tables part no. Im/c1900–mod flow totalisation ramp/soak profile maths functions timer functions part no. Im/c1900–adv advanced software options specification sht. Full specification part no. Ss c1900 part no. Im/c1900—ins ins...

  • Page 4

    2 commander 1900 single pen recorder electrical code – standard option module – none options – none door lock – not fitted power supply – 115v ac modules fitted in module positions 2 to 6 – none special settings – company standard 1901j a 0 0 1 1 00000 std push to release handle pull handle to relea...

  • Page 5

    3 + 0 to 95% rh 0 to 80% rh 55°c (131°f) max. 0°c (32°f) min. A – within temperature limits b – within humidity limits c – use screened cables 12.63 (320.8) 12.63 ( 320.8) 0.32 (8.3) 2.23 (56.8) 1.18 (30.1) 1.18 (30.1) dimensions in inches (mm) 2.60 (66) 1.38 (35.1) 0.94 (22.4) 7.22 (183.4) 1.44 (36...

  • Page 6

    4 3.2.1 wall-/pipe-mounting – fig. 3.4 fig. 3.4 wall-/pipe mounting …3 mechanical installation b – pipe-mounting (optional) a – wall-mounting (optional) 3 2 4 mark fixing centers on wall (4) drill suitable holes (4) secure instrument to wall using suitable fixings 14.81 (376.3) 11.06 (281.0) secure ...

  • Page 7

    5 3.2.2 panel mounting – fig. 3.5 3 mechanical installation locate instrument in cut-out secure in panel using four bolts, washers and nuts drill four suitable holes optional gasket (see note 2 below) 4 5 3 dimensions in inches (mm) cut hole in panel (see note 1 below) mark four mounting holes 12.72...

  • Page 8

    6 1 unplug module 3 2 release clip remove terminal block assembly warnings. • instruments not fitted with the optional internal on/off switch and fuse must have a disconnecting device such as a switch or circuit breaker conforming to local safety standards fitted to the final installation. It must b...

  • Page 9

    7 additional functions channel 3 (blue pen) module positions 1 2 3 4 5 6 channel 4 (black pen, violet event pen or additional functions) not available on non-upgradeable version see note below additional functions channel 2 (green pen) channel 1 (red pen) 4.1 identifying the input/output modules – f...

  • Page 10

    8 …4 electrical installation p osition 1 p osition 2 p osition 3 p osition 4 p osition 5 p osition 6 ic5 pl1 8 5 4 1 pl8 4 1 ic12 c87 c86 c85 c18 tr10 r17 r18 r16 r20 r25 r50 r22 r15 r48 r49 r40 mv thc ma v rtd & resistance pl1 pl1 2-wire transmitter all other input types pl8 pl8 2 1 3 4 1 4 8 5 2 1...

  • Page 11

    9 4 electrical installation… 4.2.2 voltage and current – fig. 4.5 input impedances: low voltage (mv) >10mΩ voltage >10mΩ current (ma) 100Ω 4.2.3 2-wire transmitter input – fig. 4.5 power for the transmitter is supplied by terminal 6. Note. The voltage across terminals 4 and 6 is 20v (nominal). This ...

  • Page 12

    10 2 5 4 4 5 6 l n (l) link (see note 2 below) 100% 0% 100% 0% motorized valve drive valve positioner power supply four relay module 3 6 10 10 11 11 type 1 and/or type 2 modules (see note 1 below) type 1 or type 2 module 1st module 2nd module 1st or 2nd module (n) 4 5 6 link (see note 2 below) 100% ...

  • Page 13

    11 1 2 7 8 9 10 11 12 3 4 5 6 common input 1 common input 7 input 8 input connections input 5 input 6 input 3 input 4 input 2 common output 1 common output 7 output 8 output connections output 5 output 6 output 3 output 4 output 2 or digital outputs pl2 pl2 2 1 3 4 2 1 3 4 digital inputs pl2 1 4 4.3...

  • Page 14

    12 p osition 1 p osition 2 p osition 3 p osition 4 p osition 5 p osition 6 line neutral remove plug to make connection x selector not fitted on 24v ac code label 230 115 digit 10 11 5 3 or 6 2 or 5 1 or 4 1 9 x x x x x x x x x x x x x x a – selecting the supply voltage b – power supply connections e...

  • Page 15

    13 * * * link positions module t ype (tick box) module t ype nc 1 analog output analog input logic inputs relay output + 2 – 3 4 5 6 7 c 8 l1 9 l2 10 no 1 c 12 1 ✓ nc 1 analog output analog input logic inputs relay output + 2 – 3 4 5 6 7 c 8 l1 9 l2 10 no 1 c 12 nc 1 analog output analog input logic...

  • Page 16

    14 * * link positions 1 logic i/ps (t ype 4) or logic o/ps (t ype 5) c 2 1 3 4 5 6 7 6 8 7 9 8 10 c module t ype (tick box) 2 position 6 nc 1 analog output analog input logic inputs relay output + 2 – 3 4 5 6 7 c 8 l1 9 l2 10 no 1 c 12 * * * not available on module t ype 2 4 5 2 3 4 5 (tick box) t y...

  • Page 17

    15 notes.

  • Page 18

    16 …notes.

  • Page 19

    Products & customer support products automation systems • for the following industries: – chemical & pharmaceutical – food & beverage – manufacturing – metals and minerals – oil, gas & petrochemical – pulp and paper drives and motors • ac and dc drives, ac and dc machines, ac motors to 1kv • drive s...

  • Page 20

    Abb limited howard road, st neots cambridgeshire pe19 8eu uk tel: +44 (0)1480 475321 fax: +44 (0)1480 217948 abb inc. 125 e. County line road warminster pa 18974 usa tel: +1 215 674 6000 fax: +1 215 674 7183 abb has sales & customer support expertise in over 100 countries worldwide www.Abb.Com the c...