Abcon ProShip Instruction Manual - Calibration
PROSHIP
®
9
CALIBRATION
USING ANY WEIGHT CALIBRATION
®
SYSTEM
Duringmanufacturethescaleisalreadyaccuratelycalibrated.Howeverwhenthescaleis
first set up for use it may be desired to calibrate it, or after time and use when mechanical
deviationscanoccurmakingthescalelessaccurate.Ifthescalehasbeenmovedtoa
differentaltitudeorgravitationthescalecanloseaccuracyastheweightofamassinone
location could be different to that in another location. It is also recommended to calibrate
in these circumstances.
What is the The Any Weight Calibration
®
System?
Normallywhenauserwishestocalibratetheirscale,themanufacturereitherrequeststhe
unitbesenttoitsheadoffice,serviceagentoraskthatyoupurchasespecialaccurate
andexpensiveweights.
TheAnyWeightCalibration
®
System allows you to calibrate without needing to use any
specialweights.Insteadyoucanuseanyobjectsthatyouareconfidentoftheirweightfor
easyandquickcalibration.Thiscouldbe,forexample,itemsweighedatthedeliormeat
counterinthesupermarket,bagsofpre-packedsugar,flourorevenpacksofcolacansor
coinsthatyouhavehadpre-weighedonLegalforTradescalesinthesupermarketor
market.Theweightcanbeinkg,g,lborozanddonothavetobewholeunits,i.e.could
be10.15kg,52.73kg,12.6lbor300.7lb.
HOW TO CALIBRATE
Itisrecommended,butnotessential,touseatotalweightthatisatleast50%ofthetotal
capacity.So,forexample,ifyourscalehasacapacityof16kg,thentheidealweightto
usewouldbe8-13kg.Youcouldcombinetheknownweightofseveralitems.Never
exceedthetotalcapacityofthescale.Lowercalibrationweightsareok(i.e.5Kg)ifthe
scaleisnormallyonlyusedwithitemsthatweighlessthan50%scalecapacity.
1. Turn on the power by pressing
[ON/OFF] andleaveswitchedonforatleast1minute
before proceeding to step 2 below.
2. Turn off power by pressing
[ON/OFF]
• Press
[UNIT] and [ON/OFF] at the same time, now the display will show “CALu=”
• Press
[UNIT]toselectthetypeofcalibrationunittobeused,i.e.kgorlb.
• Press
[ZERO] to enter the Weight Selection Mode. In this mode you are now able to
enter the exact weight of the item you are using to calibrate the scale.
Press
[HOLD] =increasesthevalueoftheflashingnumber
Press
[UNIT] =movestonextnumberontheright