- DL manuals
- Accu-Chek
- Blood Glucose Meter
- Compact Plus
- Reference Manual
Accu-Chek Compact Plus Reference Manual - page 4
4
Farbe: P 249 – Prüfmittelnummer: 126 X
Contents
5
Contents
6 Checking your meter
................................................................ 96
7 Cleaning your Accu-Chek Compact Plus system
................. 107
7.1 Cleaning the meter .......................................................... 107
7.2 Cleaning the finger pricker .............................................. 111
8 Blood glucose testing in a multi-patient setting -
Supplementary information for healthcare professionals
... 112
8.1 Replacing the finger pricker with a blanking plate ........... 114
8.2 Testing for blood glucose ................................................ 116
8.3 Disinfecting the meter ..................................................... 120
8.4 Suitable disinfectants ...................................................... 125
9 Measurement and storage conditions
.................................. 126
9.1 Temperature range ......................................................... 126
9.2 Atmospheric humidity ..................................................... 129
9.3 Sources of interference ................................................... 129
10 Symbols, display messages and troubleshooting
................ 130
10.1 Symbols .......................................................................... 131
10.2 Display messages and troubleshooting ........................... 138
11 Technical data
........................................................................ 162
12 Disposing of your meter
........................................................ 166
13 System components
.............................................................. 167
14 Guarantee
............................................................................... 168
15 Patents
..................................................................................... 169
16 Local customer support and service
..................................... 170
16.1 Information and repair ..................................................... 170
16.2 Contact us ...................................................................... 171
17 Alphabetical index
................................................................. 172
Summary of Compact Plus
Page 1
0 45 73 18 80 01 (0 2) 11 /0 5 farbe: p 249 – prüfmittelnummer: 126 x blood glucose monitoring system reference manual a ccu- c hek ® compact plus 0088 accu-chek and softclix are trademarks of roche. ©2005 roche diagnostics. All rights reserved. Distributed by: roche diagnostics ltd bell lane, lewes...
Page 2
1 farbe: p 249 – prüfmittelnummer: 126 x on the packaging, on the type plate of the meter and on the finger pricker you may encounter the symbols shown below. They have the following meanings: please consult instructions for use catalogue number for in vitro diagnostic use store at use by/ expiry da...
Page 3
2 farbe: p 249 – prüfmittelnummer: 126 x contents 3 contents contents 1 introduction ................................................................................ 6 1.1 the accu-chek compact plus blood glucose meter at a glance ........................................................................
Page 4
4 farbe: p 249 – prüfmittelnummer: 126 x contents 5 contents 6 checking your meter ................................................................ 96 7 cleaning your accu-chek compact plus system ................. 107 7.1 cleaning the meter .............................................................
Page 5
6 farbe: p 249 – prüfmittelnummer: 126 x introduction 7 introduction 1 6 drum release button 7 measuring window 8 test strip 9 test strip drum 10 drum compartment cover* 11 m button press this button to retrieve results stored in the meter’s memory. * available as replacement part 1 introduction 1.1...
Page 6
8 farbe: p 249 – prüfmittelnummer: 126 x introduction 9 introduction 1 back 12 battery compartment cover* 13 infrared window 14 batteries: type aaa, lr 03, am 4, micro 15 battery compartment 16 type plate 17 finger pricker* 18 control window (shows the number of strips remaining) 19 slide button for...
Page 7
10 farbe: p 249 – prüfmittelnummer: 126 x introduction 11 introduction 1 1.2 the accu-chek softclix plus finger pricker at a glance 20 plunger the plunger is a multifunction button used to prime, trigger and eject the lancet. 21 window showing the penetration depth setting 22 lancet holder 23 lancet...
Page 8
12 farbe: p 249 – prüfmittelnummer: 126 x introduction 13 introduction 1 1.3 main features the meter is supplied with batteries already inserted. The time and date are already set. You may need to adjust these settings to your own time zone (see chapter 3 “settings”). Docked finger pricker the meter...
Page 9
14 farbe: p 249 – prüfmittelnummer: 126 x introduction 15 introduction 1 acoustic mode acoustic mode is intended for persons who are visually impaired. When acoustic mode is turned on, the meter guides the user through the test- ing process using beep tones; it also outputs the result as a series of...
Page 10
16 farbe: p 249 – prüfmittelnummer: 126 x introduction 17 introduction 1 throughout this manual you will see examples of what the display looks like. Any elements that flash are shown surrounded by a halo. Example: you have turned on the meter to perform a blood glucose test. In the display you see ...
Page 11
18 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 19 initial steps before testing 2 2 initial steps before testing 2.1 checking the contents check that your monitoring kit is complete. The package contents are listed on the box. If anything is missing, please contact the accu-ch...
Page 12
20 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 21 initial steps before testing 2 remove any used batteries. Insert two new batteries (type aaa, lr 03, am 4 or micro). The minus (-) ends of the batteries must match up with the minus marks in the battery compartment. Re-attach ...
Page 13
22 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 23 initial steps before testing 2 i when the battery symbol first appears in the display the bat- teries are running low. You can perform about 50 more tests. You should, however, replace the batteries as soon as possible. By the...
Page 14
24 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 25 initial steps before testing 2 2.4 performing a full display check to check that all of the elements are properly displayed, you should carry out a full display test. Press and hold down the m button. The meter turns on. As lo...
Page 15
26 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 27 initial steps before testing 2 i if your meter is brand new and unused, it will contain a mock drum (an empty test strip drum without a label). Please remove this mock drum. Whether a test strip drum is inserted or not: press ...
Page 16
28 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 29 initial steps before testing 2 if there is a test strip drum in the meter: tip the meter forwards. The test strip drum drops out. I you can dispose of used test strip drums with your regular household waste. Insert a new test ...
Page 17
30 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 31 initial steps before testing 2 a dot appears in the small control window on the back of the meter. This indicates that you have just inserted a test strip drum. When you perform a blood glucose test, the meter counts the numbe...
Page 18
32 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 33 initial steps before testing 2 use only new test strips. Make sure the aluminium foil (the “silver ends”) is intact on both sides. Your blood glucose results may be incorrect if you use a damaged drum. Incorrect results can ca...
Page 19
34 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 35 initial steps before testing 2 test strip drum use-by period when you insert a new drum, the meter starts to count the number of days the drum has been in the meter. Each drum must be used up within a 90-day use-by period. If ...
Page 20
36 farbe: p 249 – prüfmittelnummer: 126 x initial steps before testing 37 settings 3 perform a quality control check (see chapter 6 “checking your meter”). If the test produces a correct result, you may continue to use the test strips. If the result is incorrect, you need to insert a new drum. Follo...
Page 21
38 farbe: p 249 – prüfmittelnummer: 126 x settings 39 settings 3 you must adjust the year, time and date to enable the meter to correctly allocate test results to a particular day or time. You have the option of setting the alarm clock function and hypo indica- tor, but you do not have to. The proce...
Page 22
40 farbe: p 249 – prüfmittelnummer: 126 x settings 41 settings 3 if this happens, you have to reset the year, time and date so that you can clearly distinguish between test results. If you do not set the year, time and date, a series of zeros (0:00 and 0-00) will be displayed when- ever you perform ...
Page 23
42 farbe: p 249 – prüfmittelnummer: 126 x settings 43 settings 3 press the m button to move to the next option. On 1: the beep tone is on. On 2: acoustic mode is on (see page 14). Off: the beep tone and acoustic mode are off. Press the s button to save the chosen setting. The year setting comes next...
Page 24
44 farbe: p 249 – prüfmittelnummer: 126 x settings 45 settings 3 3.3 setting the time/date format you can choose between the two formats: in 24-hour format the time is displayed from 0:00 to 23:59. If you select this format, the date is displayed in the format dd-mm (day-month). In 12-hour format th...
Page 25
46 farbe: p 249 – prüfmittelnummer: 126 x settings 47 settings 3 press the s button to save the chosen setting. The minute setting comes next. The minutes flash at top left of the display. Press the m button repeatedly until the correct minute is displayed. The meter increments the minutes. If you h...
Page 26
48 farbe: p 249 – prüfmittelnummer: 126 x settings 49 settings 3 press the m button repeatedly until the correct day is displayed. The meter increments the day. If you hold the m button down, the meter fast-scrolls forward to 31, and then starts again at 1. Press the s button to save the chosen sett...
Page 27
50 farbe: p 249 – prüfmittelnummer: 126 x settings 51 settings 3 after you have turned on the alarm clock function, you need to set the times. You can set up to three different times. However, you do not have to set all three alarm times. If you choose to enter only one or two times, press the test ...
Page 28
52 farbe: p 249 – prüfmittelnummer: 126 x settings 53 settings 3 press the s button to save the chosen setting. The minute setting comes next. The minute flashes in the display. Press the m button repeatedly until the correct minute is displayed. The meter increments the minutes. If you hold the m b...
Page 29
54 farbe: p 249 – prüfmittelnummer: 126 x settings 55 settings 3 the time 2 setting is followed by the time 3 setting. If you wish to set time 3, proceed as described for time 1. The setting for time 3 is followed by the hypo indicator setting. If you do not wish to enter a hypo indicator, press the...
Page 30
56 farbe: p 249 – prüfmittelnummer: 126 x settings 57 settings 3 off and hypo? Flash in the display. The presetting is: hypo indicator off. You can choose between the following hypo indicator levels: 3.3 mmol/l (60 mg/dl ) 3.9 mmol/l (70 mg/dl ) 4.4 mmol/l (80 mg/dl ) press the m button to move to t...
Page 31
58 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 59 testing blood glucose 4 4 testing blood glucose the accu-chek compact plus meter may be used by people with diabe- tes to test their own blood glucose as well as for blood glucose determi- nation by healthcare practitioners in a prof...
Page 32
60 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 61 testing blood glucose 4 4.1.1 undocking the finger pricker from the meter push the slide button in the direction indicated by the arrow (1) and hold it there. Withdraw the finger pricker in the direction indicated by the arrow (2). 4...
Page 33
62 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 63 testing blood glucose 4 4.1.3 inserting the lancet remove the cap from the finger pricker. Slide a new lancet into the lancet holder, and push it in until you hear it click into place. Remove the protective cap from the lancet with a...
Page 34
64 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 65 testing blood glucose 4 dropping the finger pricker with a lancet inserted may loosen the lancet in its holder. In that case the lancet is no longer properly lodged and cannot be used to obtain blood. In rare cases the lancet may eve...
Page 35
66 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 67 testing blood glucose 4 check that all the elements shown in the illustration are properly displayed on your meter. If any of the display elements are missing, please call the accu-chek customer careline free on 0800 701000 (uk) or 1...
Page 36
68 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 69 testing blood glucose 4 rotate the comfort dial (cap) until you reach your chosen setting. Choose a low setting (e.G. 2) if you are using the accu-chek softclix plus finger pricker for the first time. To collect blood you first need ...
Page 37
70 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 71 testing blood glucose 4 press in the plunger until it clicks. This triggers the lancet, which penetrates the skin. Using gentle pressure, massage the finger towards the fingertip to encourage a drop of blood to form. The amount of bl...
Page 38
72 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 73 testing blood glucose 4 always hold the meter so the test strip is pointing downwards when you are applying blood to the test strip. If you hold it so the test strip is pointing upwards or sideways or you put the meter down on a surf...
Page 39
74 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 75 testing blood glucose 4 4.2.3 ejecting the test strip hold the meter over a waste bin with the test strip pointing down- wards. Press the test button to turn the meter off. The used test strip drops out. Take care not to bend the tes...
Page 40
76 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 77 testing blood glucose 4 i if you do not turn the meter off, it turns off automatically after ap- proximately 60 seconds. The test strip then remains in the meter. When you turn on a meter which still has a test strip inserted, it sim...
Page 41
78 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 79 testing blood glucose 4 4.2.4 ejecting the used lancet remove the cap from the finger pricker. Hold the finger pricker upright above a waste bin. Press in the plunger until it clicks. The lancet drops out..
Page 42
80 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 81 testing blood glucose 4 if the lancet does not drop out: keep the plunger pressed down. Hook the edge of the white “collar” of the comfort dial (cap) behind the platform of the lancet (see illustration below). Use the white “collar” ...
Page 43
82 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 83 testing blood glucose 4 pressing the test button to turn the meter off saves the result together with the asterisk. 4.3 evaluating results 4.3.1 plausible results your meter measures blood glucose within a defined range (0.6-33.3 mmo...
Page 44
84 farbe: p 249 – prüfmittelnummer: 126 x testing blood glucose 85 testing blood glucose 4 these results are not used to calculate averages (see chapter 5.3 “av- erages, highest value and lowest value for 7, 14 and 30 days”). If the displayed test result agrees with the way you feel, follow your doc...
Page 45
86 farbe: p 249 – prüfmittelnummer: 126 x using your meter as an electronic notebook 87 using your meter as an electronic notebook 5 5 using your meter as an electronic notebook 5.1 memory your meter has a 300-value memory for saving results together with time and date (provided you have set the tim...
Page 46
88 farbe: p 249 – prüfmittelnummer: 126 x using your meter as an electronic notebook 89 using your meter as an electronic notebook 5 press the s button to move towards the next most recent result saved. If you hold down the s button, you scroll through your results more quickly towards the more rece...
Page 47
90 farbe: p 249 – prüfmittelnummer: 126 x using your meter as an electronic notebook 91 using your meter as an electronic notebook 5 with the meter turned off, press the m button. The meter turns on without advancing a test strip. The most recent result and mem are displayed. Press the s and m butto...
Page 48
92 farbe: p 249 – prüfmittelnummer: 126 x using your meter as an electronic notebook 93 using your meter as an electronic notebook 5 press the s and m buttons again at the same time. The average of the results from the last 30 days is displayed. For this period, too, you can request the meter to dis...
Page 49
94 farbe: p 249 – prüfmittelnummer: 126 x using your meter as an electronic notebook 95 using your meter as an electronic notebook 5 start the program on your pc or handheld computer, or on the accu-chek smart printer system, so it is ready to receive the data. Position the meter 10-20 cm away from ...
Page 50
96 farbe: p 249 – prüfmittelnummer: 126 x checking your meter 97 checking your meter 6 6 checking your meter to ensure your results are always dependable, you should periodically check the performance of your accu-chek compact plus meter. Do this by running a quality control check using accu-chek co...
Page 51
98 farbe: p 249 – prüfmittelnummer: 126 x checking your meter 99 checking your meter 6 take a bottle of control solution. Open it and wipe the tip of the dropper with a clean paper towel in order to remove any dried-on residues. Apply a drop of control solution to the surface of a clean, easily wash...
Page 52
100 farbe: p 249 – prüfmittelnummer: 126 x checking your meter 101 checking your meter 6 hold the tip of the test strip to the drop of control solution. The test strip draws up the control solution via the black notch. When the test strip has drawn up sufficient control solution, the meter beeps (pr...
Page 53
102 farbe: p 249 – prüfmittelnummer: 126 x checking your meter 103 checking your meter 6 as soon as the result is displayed and you have flagged it as a quality control test (where this is necessary): compare the result with the concentration table printed on the peel- off label attached to the drum...
Page 54
104 farbe: p 249 – prüfmittelnummer: 126 x checking your meter 105 checking your meter 6 i the hypo indicator cannot distinguish between blood and control solution. If you have set a hypo indicator and use control solution g1 you may see hypo? Flashing on the display. This means that the reading for...
Page 55
106 farbe: p 249 – prüfmittelnummer: 126 x checking your meter 107 cleaning your accu-chek compact plus system 7 is the control solution beyond its expiry date (see label on the bottle)? Has the control solution been open for more than three months? Once opened, control solutions are stable for thre...
Page 56
108 farbe: p 249 – prüfmittelnummer: 126 x cleaning your accu-chek compact plus system 109 cleaning your accu-chek compact plus system 7 clean the meter carefully if the test strip guide has become visibly soiled, message e-5 is displayed (see page 151). If the meter is on, press the test button to ...
Page 57
110 farbe: p 249 – prüfmittelnummer: 126 x cleaning your accu-chek compact plus system 111 cleaning your accu-chek compact plus system 7 remove any fluff or lint that may remain. Close the drum compartment cover and push it shut. You will hear an audible click. Perform a quality control check (see c...
Page 58
112 farbe: p 249 – prüfmittelnummer: 126 x 112 blood glucose testing in a multi-patient setting 113 113 blood glucose testing in a multi-patient setting 8 8 blood glucose testing in a multi-patient setting - supplementary information for healthcare professionals the use of the same accu-chek compact...
Page 59
114 farbe: p 249 – prüfmittelnummer: 126 x 114 blood glucose testing in a multi-patient setting 115 115 blood glucose testing in a multi-patient setting 8 8.1 replacing the finger pricker with a blanking plate the accu-chek softclix plus finger pricker is intended for patient self-monitoring by a si...
Page 60
116 farbe: p 249 – prüfmittelnummer: 126 x 116 blood glucose testing in a multi-patient setting 117 117 blood glucose testing in a multi-patient setting 8 8.2 testing blood glucose wear protective gloves. Wash or disinfect the patient’s finger and allow it to dry thoroughly. The drop of blood cannot...
Page 61
118 farbe: p 249 – prüfmittelnummer: 126 x 118 blood glucose testing in a multi-patient setting 119 119 blood glucose testing in a multi-patient setting 8 touch the tip of the test strip against the drop of blood. The test strip draws up the blood through the black notch. While the test strip is dra...
Page 62
120 farbe: p 249 – prüfmittelnummer: 126 x 120 blood glucose testing in a multi-patient setting 121 121 blood glucose testing in a multi-patient setting 8 8.3 disinfecting the meter the accu-chek compact plus meter may be disinfected. Disinfection is performed according to the degree of soiling (see...
Page 63
122 farbe: p 249 – prüfmittelnummer: 126 x 122 blood glucose testing in a multi-patient setting 123 123 blood glucose testing in a multi-patient setting 8 once you have opened the drum compartment cover, you will see beneath it the small measuring window (1) and have access to the lower edge of the ...
Page 64
124 farbe: p 249 – prüfmittelnummer: 126 x 124 blood glucose testing in a multi-patient setting 125 125 blood glucose testing in a multi-patient setting 8 when to disinfect each time after you have tested a patient’s blood glucose: wipe the area around the test strip guide. If you find blood on the ...
Page 65
126 farbe: p 249 – prüfmittelnummer: 126 x 126 measurement and storage conditions 127 127 measurement and storage conditions 9 9 measurement and storage conditions the reliability of your meter and finger pricker as well as the accuracy of your results may be influenced by a number of factors. Pleas...
Page 66
128 farbe: p 249 – prüfmittelnummer: 126 x 128 measurement and storage conditions 129 129 measurement and storage conditions 9 never expose the finger pricker to high temperatures (e.G. In a hot car). High temperatures can cause parts of the finger pricker to become warped, so impairing its operatio...
Page 67
130 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 131 symbols, display messages and troubleshooting 10 10 symbols, display messages and troubleshooting in addition to test results, the time and the date, your meter also dis- plays other symbols and error messag...
Page 68
132 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 133 symbols, display messages and troubleshooting 10 symbol... Meaning: mem signifies that the result being displayed is a result from memory. No results have been saved. The meter cannot calculate the aver- age...
Page 69
134 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 135 symbols, display messages and troubleshooting 10 symbol... Meaning: when this result was saved, the tem- perature was at the limit of the permit- ted range. Do not use the result as a basis for therapeutic d...
Page 70
136 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 137 symbols, display messages and troubleshooting 10 symbol... Meaning: the blood glucose result is above the measuring range, i.E. It is greater than 33.3 mmol/l (or 600 mg/dl). If the test result agrees with t...
Page 71
138 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 139 symbols, display messages and troubleshooting 10 10.2 display messages and troubleshooting when elements in the display are surrounded by a halo, it indicates that they are flashing in the meter’s display. I...
Page 72
140 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 141 symbols, display messages and troubleshooting 10 if this happens … it means: the clock has stopped or the clock is slow. The meter was exposed to a tem- perature below –10 °c and the bat- teries are beginnin...
Page 73
142 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 143 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: you are requested to perform a quality control check in order to check the test strips. The meter has no way of tellin...
Page 74
144 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 145 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: the 90-day use-by period for the test strip drum has expired. The test strips cannot be used. You must not use these t...
Page 75
146 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 147 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: although you performed a quality control check, the bottle symbol is not dis- played. An assignment error has occurred...
Page 76
148 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 149 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: the bar code on the test strip drum is damaged. If you inserted the first drum from a pack, remove the drum from the m...
Page 77
150 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 151 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: all test strip drums from the same pack have a bar code that is valid for this pack only. Do not code the meter with t...
Page 78
152 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 153 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: you applied blood or control solution too soon. Press the test button to turn the meter off and then on again. Repeat ...
Page 79
154 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 155 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: you pulled the test strip out of the meter before applying blood or con- trol solution to the strip. Press the test bu...
Page 80
156 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 157 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: you pulled the test strip out of the meter during testing. Press the test button to turn the meter off and then on aga...
Page 81
158 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 159 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: the meter has been exposed to severe differences in temperature. The temperature is too low (between 0 °c and +6 °c) o...
Page 82
160 farbe: p 249 – prüfmittelnummer: 126 x symbols, display messages and troubleshooting 161 symbols, display messages and troubleshooting 10 this message/symbol appears… and means: a meter error has occurred. Press the test button to turn the me- ter off and then on again. If the error message pers...
Page 83
162 farbe: p 249 – prüfmittelnummer: 126 x technical data 163 technical data 11 11 technical data meter type accu-chek compact plus catalogue no./serial no. See type plate on back of meter test principle determination of glucose in fresh capil- lary blood by reflectance photometry. When using differ...
Page 84
164 farbe: p 249 – prüfmittelnummer: 126 x technical data 165 technical data 11 power supply 2 batteries (type aaa, lr 03, am 4 or micro) or 2 nimh rechargeable batteries (type aaa) battery life approx. 1000 results (fewer in acoustic mode, owing to higher battery load, or when rechargeable batterie...
Page 85
166 farbe: p 249 – prüfmittelnummer: 126 x disposing of your meter 12 167 system components 13 13 system components use only accu-chek compact test strips for testing with the accu-chek compact plus meter. These are available from your pharmacist. Only accu-chek compact control and accu-chek compact...
Page 86
168 farbe: p 249 – prüfmittelnummer: 126 x guarantee 14 169 patents 15 14 guarantee the statutory provisions on rights in consumer goods sales in the country of purchase shall apply. 15 patents accu-chek compact plus meter ep 732 590; ep 738 666; ep 742 436; ep 1 189 064; us 5,463,467; us 5,720,924;...
Page 87
170 farbe: p 249 – prüfmittelnummer: 126 x local customer support and service 171 local customer support and service 16 16 local customer support and service 16.1 information and repairs information service if you have any questions on how to use your accu-chek compact plus meter or accu-chek softcl...
Page 88
172 farbe: p 249 – prüfmittelnummer: 126 x alphabetical index 173 alphabetical index 17 16.2 contact us accu-chek customer careline: freephone: 0800 701000 freephone rep. Of ireland: 1 800 709600 roche diagnostics ltd bell lane, lewes east sussex, bn7 1lg united kingdom web: www.Accu-chek.Co.Uk 17 a...
Page 89
174 farbe: p 249 – prüfmittelnummer: 126 x alphabetical index 175 alphabetical index 17 blanking plate ......................................................................... 114, 167 blood applying to test strip ................................................................ 71 collecting .........
Page 90
176 farbe: p 249 – prüfmittelnummer: 126 x alphabetical index 177 alphabetical index 17 f finger pricker ......................................................................... 8, 12, 58 description ....................................................................... 10 - 11 docking ..............
Page 91
178 farbe: p 249 – prüfmittelnummer: 126 x alphabetical index 179 p patents ........................................................................................... 169 penetration depth ....................................................................... 58, 67 penetration depth setting ........
Page 92
180 farbe: p 249 – prüfmittelnummer: 126 x flashing ........................................................................... 16, 130 hi .................................................................................... 83, 136 hypo? .................................................................