Airone PARSIFAL INOX 120 Instruction Manual - page 5
In the INOX version, the gluing of the cover (as rule, use the same material of the work top) of the
downdraft, must be performed in the same place after finishing the assembly of the downdraft. The
space between the lid and hole on the top should be about 1.5mm long the whole perimeter.
The support for the gluing of the cover is supplied with the downdraft.
The controls must be assembled in order to guarantee an eventual attendance of technical
assistance. The label with the technical information is placed on the lid of the wiring box / command.
Caution: In the kitchen furniture, provide in front or behind of the downdraft a removable wall to
allow technicians to remove the front or rear panel of the hood in case of assistance.
The assistance must be performed by authorized specialists.
Failure to comply with this condition, significant increased costs could be charged in the case of
assistance.
It is possible to connect on the front or on the back part of the downdraft a tube of diameter 150 or
200mm according to the suction motor used.
Remove the lid traced out before with the help of a hammer and fix the flange with 4 screws already
included. Then connect the tube.
It is possible to connect on the side of the downdraft a tube of diameter 150mm on both sides and
preferably on two heights.
Remove the lid traced out before with the help of a hammer. After having decided the position of the
holder, unscrew the screws on the same hood. Secure the holder and connecter already included by
re-screwing the screws of the hood. Then connect the tube.
CONTROLS POSITIONING
The flat controls has a thickness of 1.5mm and is stickered to the bottom. It is also equipped with a
2mt cable which permits the client to position it on the front or inside a drawer.