ELECTRIC WIRING
Safety Instructions:
Before any manipulation of the controller power cord (230 volt)
Before each operation, all devices connected
Electrical connections must be performed by professionals
Warning : Make all wiring connections to the wiring box before connecting the power supply 230V.
Failure to observe this procedure can cause severe damages to electronics.
For connections between hood and wiring box, refer to the following indications :
1) External motor connector
2) Power supply 230V
3) Cable with faston for microswich hood
4) Remote control antenna cable (has to remain free)
5) Flat control cable
6) Hood activator cable
After connecting the activator connector (6), close the opening of the box with the lid already
included.
1
2
3
4
5
6