Ansal BlueStar Installation Manual - Installation Place
The Indoor Unit
The Outdoor Unit
There is enough room for installation and maintenance.
The ceiling is horizontal, and its structure can endure the weight of the indoor unit.
The air outlet and the air inlet are not impeded, and the influence of external air is the least.
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out easily.
There is no direct radiation from heaters
INSTALLATION PLACE
Location in the following places may cause malfunction of the machine. (If unavoidable,
please consult your local dealer.)
a. There exists petrolatum.
b. There is salty air surrounding(near the coast).
c. There is caustic gas(the sulfide, for example) existing in the air (near a hot spring).
d. The Volt vibrates violently(in the factories).
e. In buses or cabinets.
f. In kitchen where it is full of oil gas.
g. There is strong electromagnetic wave existing.
h. There are inflammable materials or gas.
i. There is acid or alkaline liquid evaporating.
j. Other special conditions.
1. Select the correct carry-in path.
2. Move this unit as originally packaged as possible.
3. If the air conditioner is installed on a metal part of the building, it must be electrically
insulated according to the relevant standards to electrical appliances.
Cautions
There is enough room for installation and maintenance.
The air outlet and the air inlet are not impeded, and can not be reached by strong wind.
The place is dry and ventilative.
The support is flat and horizontal and can stand the weight of the outdoor unit. And no
additional noise or vibration.
Your neighborhood will not feel uncomfortable with the noise or expelled air.
There is no leakage of combustible gas.
It is easy to install the connecting pipe or cables.
Notes Before Installation
2