Baer UniMod Ethernet Operation Manual - page 11
UniMod Ethernet
11
Telnet access
For purposes of service it is possible to access an UniMod Ethernet via the Telnet tool, which is
delivered with Windows. You can start it using the “Execute” button in the Start menu, or by enter-
ing “telnet” in a DOS box. Help is offered by typing “help” at telnet’s command prompt.
Procedure:
Open connection ( “open
Read current modem settings using AT commands (e.g. AT&V
). Please note that the “AT”
part is already printed, only the following command specifier must be entered.
The command ATZ resets the modem.
Starting with v
ersion „ETHERNET V3“ (can be queried using ATI command) access must be ena-
bled by entering username and password. Default values are
“insys”/”insys”. In this version the
modem-reset must be requested using AT#RESET, the ATZ command is functionless.
7. Reset Function
Optional it is possible to activate the time-controlled modem-reset. The functionality is activated by
the jumper and displayed by the Rst-LED (Rst-LED flashes every 10 seconds).
Reset-Timer
Jumper
Function
Rst-LED
Disable: without re-
sets
never flashes
24h: reset every 24
hours (standard)
12h: reset every 12
hours
6h: reset every 6
hours
Without jumper: reset
every 3 hours