9. Technical Data
Housing:
Wall-mounted housing (DIN 43861-2)
Degree of protection:
IP52 (IEC)
Dimensions:
W = 105 mm,
H = 179 mm
D = 72 mm
Protection class:
2
Supply voltage:
80VAC to 270VAC or 60VDC to 375VDC
Power consumption:
About 4 VA
(depends upon supply voltage, kind of interface
module and operating status of transmission unit)
Interfaces:
Plug-in modules; available are:
- RS232 (supports signals RxD, TxD, RTS, CTS, GND, DTR,
DCD/DSR)
- CS (20mA current loop) active or passive
- RS485
- M-Bus active: can supply 20 devices max.
Display:
LED’s for signals: operation, Rst, Hook, DCD, TxD and RxD
Transmission rate remote
modem to UniMod:
10 Mbits/s (IEEE802.3)
Ethernet connection:
10 Base-T
Protocols:
ARP, ICMP, TCP/IP, UDP/IP
Transmission rate UniMod
to connected device:
300 to 19200 Baud
Data format:
7E1, 8N1, 8E1, ...
Software-Interface:
Hayes Standard-AT commands
Data Transmit Control:
Possible
Reset function:
Possible: every 3, 6, 12 or 24 hours
Extent of delivery:
- UniMod Ethernet including interface module as ordered
- RJ45 connector
- Operation manual
Accessories:
- Adapter for parameterization with RS232 port (Order No.: #9177)
- Adapter for parameterization with USB port (Order No.: #12823)
- Additional interface modules
- Suspension eye (Order No.: #9141)
- Software UniModSet