Bandit 240 PB Installation And User Manual

Other manuals for 240 PB: Installation Manual

Summary of 240 PB

  • Page 1

    Bandit 240 pb installation and user guide ©2006 all rights reserved bandit solutions, inc. Distributed by: detection dynamics, inc. 6606 n. Lamar blvd., suite 300 austin, texas 78752 (512) 453-1133 • www.Cctvpros.Com.

  • Page 2: Safety Symbols

    Bandit 240 pb installation and user guide 2 safety symbols the following symbols are used in this installation guide to indicate possibly hazardous conditions. Electrical hazard—failure to observe the danger notice may result in electrical shock, severe bodily injury, or death. Caution—failure to ob...

  • Page 3: Installation

    Bandit 240 pb installation and user guide 3 installation mounting site selection select a site for mounting bandit 240 pb with the following characteristics: • ambient temperate between 32–122ºf. Avoid locations close to heat sources such as radiators and stoves. • clearance from walls and ceiling a...

  • Page 4

    Bandit 240 pb installation and user guide 4 • avoid pointing the nozzle to an air circulation point, such as an open window, a window that may be broken during a burglary, or a large circulation vent; in such cases the nozzle may eject the fog directly outside of the protected area. • point the nozz...

  • Page 5

    Bandit 240 pb installation and user guide 5 mounting procedure—wall 1. Select a mounting location. Be sure the location you select complies with the requirements listed in the section “site selection” on page 3. 2. If you ordered the optional handy-boy jig, place bandit 240 pb on the jig. 3. Connect...

  • Page 6: Electrical Connection

    Bandit 240 pb installation and user guide 6 7. Attach the mounting plate using screws 8. Position and secure bandit on the mounting plate. 9. If you ordered the optional extended ejection nozzle, attach it to bandit through the 2" hole. Proceed to “electrical connection.” electrical connection cauti...

  • Page 7: Connecting Accessories

    Bandit 240 pb installation and user guide 7 3. Open the rear cover on bandit. 4. Locate the 3-way terminal block for 110 vac power. 5. Connect power leads as follows: red to n, black to l, and ground to ground. 6. Route power cable through strain relief. 7. Reapply power to electrical line. 8. With ...

  • Page 8: Maintenance

    Bandit 240 pb installation and user guide 8 led indication power blinking red power supply disconnected or main fuse blown and bandit not in guard mode. The following table lists the conditions of the green led on the hy-3 pak sleeve. Solid green canister installed properly and armed. Blinking green...

  • Page 9: Periodic Maintenance

    Bandit 240 pb installation and user guide 9 4. Unscrew the red allen bolts on the canister assembly and remove the old canister. 5. Insert the new canister into the canister assembly and tighten allen bolts. 6. Insert canister assembly into bandit 240 pb and tighten allen bolts. 7. Replace side hatc...

  • Page 10

    Bandit 240 pb installation and user guide 10 troubleshooting and technical support leave all repairs to authorized persons and/or the manufacturer. For technical support, contact your distributor: detection dynamics, inc. 6606 n. Lamar blvd., suite 300 austin, texas 78752 (512) 453-1133 www.Cctvpros...