Banner Q3X Instruction Manual - page 19
NOTE: To program the sensor using remote input, remote input must be enabled (
=
)
1. Present the target.
Method
Action
Result
Push Button
Present the target. The sensor-to-target distance must be within the
sensor's range.
The target's value displays.
Remote Input
2. Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold TEACH for longer than 2 seconds.
and
flash alternately
on the display. The WND indicator
flashes.
Remote Input No action required.
n/a
3. Teach the sensor.
Method
Action
Result
Push Button
Press TEACH to teach the target.
The sensor sets the window and
returns to Run mode.
Remote Input Single-pulse the remote input.
T
flashes briefly on the display
and the sensor returns to Run mode.
Table 5: Expected TEACH Behavior for Window Set
Condition
TEACH Result
Display
A valid condition is detected.
Sets a symmetric window around the
taught condition. The threshold window
is set by the
value.
The current NSS displays.
The taught condition is at a valid low
signal level.
Sets a symmetric window around the
taught condition, using the minimum
offset value.
The achieved percent briefly displays,
and then the current NSS displays.
The taught condition is less than the
minimum detection range.
Sets a single threshold at the minimum
level. Sets the sensor at the maximum
detection condition.
briefly displays, and then the
current NSS displays.
The taught condition plus the offset is
greater than the detection range.
Sets a single threshold at the
maximum level. Sets the sensor at the
minimum detection condition.
briefly displays, and then the
current NSS displays.
3.5.5 Light Set
Light set sets a switching threshold a user-selectable percent offset below the presented condition. Use the
menu to
set the offset percentage. The default is 20%.
Q3X Laser Contrast Sensor
www.bannerengineering.com - Tel: 763.544.3164
19