  • Page 1

    Be1-50/51b retrofit kits the be1-50/51b time overcurrent relay retrofit kits provide economical, modern replacements for electromechanical overcurrent relays in a variety of applications. Advantages • self powered from 50/60hz systems, available for 5 or 1 amp ct secondaries. • field selectable curv...

  • Page 2: Features

    Be1-50/51b retrofit kits features • 15 field selectable, inverse, fixed time and british standard (bs142) time overcurrent curves on 200 series relays (10 on 100 series). • time characteristics extend to 40 x pickup. • instantaneous overcurrent function. • wide setting ranges: time overcurrent: 0.5 ...

  • Page 3: Functional Description

    Be1-50/51b retrofit kits 3 functional description table 2. Current sensing capabilities time element time element 50/60 hz system time element max. Continuous max. Current instantaneous time element instantaneous ct secondary pickup range current for 1 second pickup range pickup accuracy pickup accu...

  • Page 4

    Be1-50/51b retrofit kits 4 functional description, continued figure 3 - side view, 50-b adjustments, be1-50/51b-235 and -236 figure 4 - side view, 50-b adjustments, be1-50/51b-230, -234, -237, -238, -239 and -244 230, 237, 239 234, 238 a: units a. Amps x 0.2 b: tenths b. Amps x 0.02 235 236 a: units...

  • Page 5: Specifications

    Be1-50/51b retrofit kits 5 current sensing input: 5 amp unit 14.0 amps 400 amps 1 amp unit 2.8 amps 80 amps continuous one second current current time pickup range: 5 amp unit: 0.5 to 15.9 amps in 0.1 amp steps 1 amp unit: 0.1 to 3.18 amps in 0.02 amp steps time dropout: not less than 95% of pickup ...

  • Page 6: Specifications, Continued

    Be1-50/51b retrofit kits 6 specifications, continued retrofit features the be1-50/51b-214, -215, -225, -230, -231, -234, -237, and -238 retrofit kits consist of a cradle, an adapter plate, and a cover and provides for installing a basler be1-50/51b single-phase time overcurrent relay in an existing ...

  • Page 7

    Be1-50/51b retrofit kits 7 notes: 1. * = any digit covering all pickup ranges, instantaneous, non-instantaneous, and 50 hz and 60 hz models. 2. Units with instantaneous elements are designated with a "b" for the eighth character in the model number. Sfc models that may be retrofitted with the be1-50...

  • Page 8: Ordering

    Be1-50/51b retrofit kits ordering model number: be1-50/51b time overcurrent relay how to order: designate the model number and the three-digit number from table 3 to define the configuration desired. Note: existing case must have appropriate terminals for a multiple element relay. Complete co replac...