MODEL NUMBER: BE1-50/51B Time Overcurrent Relay
How to order: Designate the Model Number and the three-digit number from Table 3 to define the configuration desired.
NOTE: Existing case must have appropriate terminals for a multiple element relay.
Complete CO replacement relay
2
BE1-50/51B-244
with same terminal connections as CO units.
New case fits FT-11 size cutout.
Retrofit kit for CO relays.
1
BE1-50/51B-219
Cradle plugs into existing case.
A new cover included.
Retrofit kit for CO relays (FT-21 case).
1
BE1-50/51B-240
Replacement glass for existing cover is included.
Cradle plugs into existing case.
Retrofit kit for CO relays (FT-21 case).
2
BE1-50/51B-241
Replacement glass for existing cover is included.
Cradle plugs into existing case.
Retrofit kit for CO relays
2
BE1-50/51B-235
Cradle plugs into existing case.
New cover included.
Complete IAC replacement relay
1
BE1-50/51B-232
with same terminal connections as IAC units.
S1 style case.
Complete IAC replacement relay
1
BE1-50/51B-218
with 50 and 51 on shared terminals.
S1 style case.
Complete IAC66K replacement relay
2
BE1-50/51B-239
with same terminal connections as IAC66K units.
S1 style case with cover.
Retrofit kit for IAC66K relay
2
BE1-50/51B-230
Cradle plugs into existing case.
Adapter plate, new cover, and connection plug included.
Retrofit kit for IAC relays
1
BE1-50/51B-214
Cradle plugs into existing case.
BE1-50/51B-215
Adapter plate, new cover, and connection plug included.
BE1-50/51B-231
Retrofit kit for IAC relays
2
BE1-50/51B-237
Cradle plugs into existing case.
Adapter plate, new cover, and connection plug included.
Retrofit kit for SFC relays
1
BE1-50/51B-229**
Cradle plugs into existing case.
Adapter plate, new cover, and connection plug included.
Retrofit kit for CO relays
1
BE1-50/51B-226
Cradle plugs into existing case.
New cover included.
Retrofit kit for CO relays
2
BE1-50/51B-236
Cradle plugs into existing case.
New cover included.
Complete IAC replacement relay
1
BE1-50/51B-228
with same terminal connections as IAC units.
S1 style case.
Retrofit kit for IAC66K relay
2
BE1-50/51B-234
Cradle plugs into existing case.
Adapter plate, new cover, and connection plug included.
Retrofit kit for IAC relays
1
BE1-50/51B-225
Cradle plugs into existing case.
Adapter plate, new cover, and connection plug included.
Retrofit kit for IAC relays
2
BE1-50/51B-238
Cradle plugs into existing case.
Adapter plate, new cover, and connection plug included.
Number of
RETROFIT RELAY PACKAGES
Instantaneous Elements
MODEL NUMBER
Table 3.
5 Amp System CT Secondaries
1 Amp System CT Secondaries
** See notes on page 7 for SFC compatibility information.
STANDARD ACCESSORY:
A test plug (Basler P/N 10095) is available to
allow testing of the relay without removing external wiring.
Printed in U.S.A.
www.basler.com
12570 State Route 143, Highland, Illinois 62249-1074 USA
Tel +1 618.654.2341 Fax +1 618.654.2351
e-mail: info@basler.com
No. 59 Heshun Road Loufeng District (N),
Suzhou Industrial Park, 215122, Suzhou, P.R.China
Tel +86(0)512 8227 2888 Fax +86(0)512 8227 2887
e-mail: chinainfo@basler.com
P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE
Tel +33 3.88.87.1010 Fax +33 3.88.87.0808
e-mail: franceinfo@basler.com
111 North Bridge Road #15-06 Peninsula Plaza
Singapore 179098
Tel +65 68.44.6445 Fax +65 65.68.44.8902
e-mail: singaporeinfo@basler.com