Biosystems MultiPro Reference Manual - ↔
26
The MODE button is used to make all
selections in the Advanced Menu.
1. Click the MODE button once to advance
to the next menu screen
2. Click the MODE button three times in
rapid succession to enter the submenu
for the menu item that is currently shown.
3. Hold the MODE button for three full
seconds to exit the advanced menu.
Once a submenu has been entered:
1. Click the MODE button once to advance
to the next item in the submenu you’ve
entered.
2. Hold the MODE button to modify the
setting.
3. Click the MODE button three times in
rapid succession to return to the Main
Menu.
6.2 Set
options
The set options submenu houses the
controls for the following items:
• STEL (on or off)
• TWA (on or off)
• Security beep (on or off)
• Alarm Latch (on or off)
• Cal Due Use (on or off)
• Upload Cal (on or off)
Once the Set options submenu is entered,
the MultiPro will automatically scroll through
the options at 5-second intervals. To change
a setting for on to off (or vice-versa) hold the
MODE button down for 1-2 seconds.
Once the settings have been modified as
needed, click the MODE button three times in
rapid succession to return to the Main Menu.
STEL and TWA Alarms are discussed in
Appendix A.
The Security Beep is covered in section
1.4.5.
Alarm Latch settings are described in section
1.4.6.
The Cal Due Use setting determines weather
the instrument can be used when it is due for
calibration. Selecting “Cal Due Use On” will
allow the MultiPro to be used when it is due
for calibration. Selecting “Cal Due Use Off”
will cause the MultiPro to be shut down if the
calibration is due and not performed
immediately upon instrument turn on.
With the Upload Cal set to “on”, the MultiPro
will automatically enable the IrDA port and
attempt to download the results of calibration
to a PC immediately following the calibration.
This is designed mostly for users of the IQ
Datalink Program. In the default
configuration, Upload Cal is set to “off”, and
the instrument will turn off following
calibration.
6.3 Set
time
When the set time option is accessed, the
screen will alternate between the hours and
minutes screens. The hours screen is given
in 24-hour format. The two screens will
alternate every 5 seconds.
↔
Click the MODE button once to change the
selection from hours to minutes (or vice
versa).
Hold the MODE button down to advance the
figure that is currently displayed (hours or
minutes).
Once the time has been correctly set, click
the MODE button three times in rapid
succession to return to the Main Menu.
6.4 Set
date
The set date submenu is divided into year,
month and day screens. The MultiPro will
automatically scroll through the Year, Month
and Day screens at 5-second intervals.
Click the MODE button once to advance
through the year, month and day screens.
Hold the MODE button down to advance the
year, month or day while the specific setting
is shown.
Once the date has been correctly entered,
click the MODE button three times in rapid
succession to return to the Main Menu.
6.5 Set
alarms
Once the “Set Alarms” submenu has been
reached, the MultiPro will display the Default
Alarms screen and then begin scrolling
through the various alarm levels.
Click the MODE button once to advance
through the screens.
When the alarm that you want to change is
shown, hold the MODE button down to
advance the counter until the appropriate
level is shown. If the alarm level you require
is lower than the current setting, allow the