    Powder auto fill for ultra-2 installation & operating guide bunn-o-matic corporation post office box 3227 springfield, illinois 62708-3227 phone: (217) 529-6601 fax: (217) 529-6644 to ensure you have the latest revision of the operating manual, or to view the illustrated parts catalog, programming m...

  • Page 2

    2 29793.1 030912 bunn-o-matic commercial product warranty bunn-o-matic corp. (“bunn”) warrants equipment manufactured by it as follows: 1) airpots, thermal carafes, decanters, gpr servers, iced tea/coffee dispensers, mcp/mca pod brewers thermal servers and thermofresh servers (mechanical and digital...

  • Page 3

    3 introduction this equipment supplies a liquid mix to the hoppers on the ultra-2 dispenser. It is for indoor use only on a sturdy counter or shelf. 00656.0001 00986.0000 user notices carefully read and follow all notices on the equipment and in this manual. They were written for your protection. Al...

  • Page 4

    4 operating instructions 1. On the ultra touch pad, make the following set- tings: a) power- “on” b) day/night- “day” 2. Pull the powder auto-fill fully forward on its sup- port rails and open the door. 3. Fill the powder auto-fill product hopper as fol- lows: a) pull the slide gate closed on the po...

  • Page 5

    5 adjustments when using the powder auto-fill with a new powdered granita mix, follow the procedure outlined below to adjust the powder auto-fill to produce the correct recipe. 1. Determine the mix ratio of powdered granita mix. Convert the recipe so that it is expressed in terms of weight units [gr...

  • Page 6

    6 ejector elbow auger auger drive shaft auger drive bracket spacer retaining ring wiper blade shaft wiper blade wiper drive gear hopper base slide gate mixing chamber whipper chamber frother dispense tip whipper chamber receptacle o-ring cleaning recommended daily cleaning and maintenance tips this ...

  • Page 7

    7 fault list door lamp fault on normal operation - powder auto-fill ready to dispense flashes on/off at 50% duty cycle low product level in powder auto-fill hopper two flashes about every 2 seconds ultra/powder auto-fill probe circuit open three flashes about every 2 seconds powder auto-fill hopper ...