Cabletron Systems WPIM-DDS Management Manual - 2.3.2
WPIM-DDS Configuration
WPIM-DDS Local Management Guide
2-9
2.3.2
WPIM-DDS Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Refer to Figure 2-2 and proceed with the following steps to configure the
WAN Interface through Local Management.
1. Use the arrow keys to highlight Interface Number. Set the WAN
connection Interface Number by typing the same number found in the
Interfaces field on the WAN Physical Configuration screen into the
Interface Number field, then press ENTER. In this example, the
Physical Configuration screen shown in Figure 2-1 uses Interface 002
for the WPIM-DDS WAN connection.
2. Use the arrow keys to highlight Line Coding. Press the SPACE bar to
select None, then press ENTER.
3. Use the arrow keys to highlight Active Protocol. Press the SPACE bar
to select PPP or FR, then press ENTER.
a.
If you selected PPP, use the arrow keys to highlight PPP Type.
Press the SPACE bar to select BNCP or LEX, then press ENTER.
Go to Step 4.
b. If you selected FR, use the arrow keys to highlight FR LMP. Press
the SPACE bar to select T1.617-D, Q.933-A, or NO LMI, then
press ENTER.
If you selected NO LMI, complete the following:
•
Use the arrow keys to highlight DLCI Address. This field can
be set to values from 0-1023. The values 16-991 are typically
used for virtual circuits.
•
Use the arrow keys to highlight Circuit State. Press the
SPACE bar to select Active, then press ENTER.
4. Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “Save Done!” appears and Local Management saves the
changes to memory.
The WAN configuration is complete. It takes up to 60 seconds for the
WAN Interface to come out of standby and for communications to begin.
NOTE
Upon saving this screen, the interface just configured is
assigned to an application port (PT#) in the table on the right
hand side of the screen once the device starts communicating
with the service provider’s switch.