the hearth.
• Variations in colour of the painted or ceramic/serpentine parts and craquelure ceramics as they are natural
characteristics of the material and product use.
• Masonry work.
• Plant parts (if present) not supplied by the manufacturer.
Any technical interventions on the product to eliminate the above-said defects and consequent damages must
be agreed upon with the Technical Assistance Centre, who reserves the right to accept the relative appointment
or not. However, said interventions will not be carried out under warranty but as technical assistance to be
granted at part of any eventual and specific agreed conditions and in accordance with the fee in force for the
work to be carried out.
The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering
or damage to the appliance, not attributable to original faults.
Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and
acoustic pollution.
The company declines all liability for any damage which may be caused, directly or indirectly, to persons,
animals or objects as a consequence of non compliance with any prescription specified in the manual, especially
warnings regarding installation, use and maintenance of the appliance.
3.1
SPARE PARTS
In the event of a malfunction, consult the retailer who will forward the call to the Technical Assistance Service.
Use only original spare parts. The retailer or service centre can provide all necessary information regarding spare
parts.
We do not recommend waiting for the parts to be worn before having them replaced. It is important to perform
regular maintenance.
The company declines all liability if the product and any other accessory is used improperly
or modified without authorisation.
All parts must be replaced with original spare parts.
4
WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT
The owner is the sole party responsible for demolishing and disposing of the product. This must be performed in
compliance with laws related to safety and environmental protection in force in his/her country.
At the end of its working life, the product must not be disposed of as urban waste.
It must be taken to a special differentiated waste collection centre set up by the local authorities or to a retailer
that provides this service.
Separating and recycling prevents potential negative effects on the environment and health (often caused by
inappropriately disposing of product parts). It also allows materials to be recovered in order to obtain significant
savings in energy and resources.
4.1
RULES FOR INSTALLATION
RULES FOR INSTALLATION
The product is a boiler that uses wood pellets.
Below is a list of the European regulations regarding the installation of the product:
EN 303-5:2012: Solid fuel boilers, with manual or automatic loading, nominal thermal power of 500 kW -
Terminology, requisites, tests and marking.
EN 12828 Heating systems design.
Electrical systems with rated voltage not exceeding 1000 V AC and 1500 V DC.
EN 1443 General chimney regulation
EN 1856-1 metal smoke ducts
EN 1856-2 metal smoke extraction channels
EN 1457 chimneys - Interior terracotta / ceramic flues
EN 13384-1 Chimneys - Thermal and dynamic fluid calculation methods - Part 1: Chimneys connected to a single
appliance
Below are some applicable regulations for Italy:
UNI 10683:2012 Heat generators fuelled by wood or other solid bio-fuels - Test, installation, control and maintenance
(for thermochemical power at the firebox lower than 35kW)
UNI/TS 11278 general technical regulation for the choice of smoke duct/flue
UNI 10847:2000 Smoke extractor systems for liquid and solid fuelled generators - Maintenance and control -
Guidelines and procedures
UNI 8065 water treatment in civil plants.
UNI 9182 Hot and cold (sanitary) air supply and distribution systems.
UNI CTI 8065 WATER TREATMENT IN THERMAL PLANTS FOR CIVIL USE
The hydraulic circuit to which the boiler is connected must compulsorily provide a circulation pump sized to
ensure adequate flow of the heat carrying fluid in any situation.