Calix T073G HGU ONT User Manual - Mounting Restrictions
10
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Mounting Restrictions
Follow the mounting restrictions below to ensure the ONT works safely:
Do not stack ONTs or stack ONTs on top of other equipment.
Ensure there is a minimum of 100 mm (4") clearance directly above the top cover of the
unit.
Ensure there is a minimum of 50 mm (2") clearance next to the side vent of the unit.
Ensure there are no external heat sources directly above or below the unit.
Laser Safety
Caution! Use of controls or adjustments, or performance of procedures
other than those specified herein may result in hazardous laser radiation
exposure.Invisible laser radiation may be emitted from the ends of un-
terminated fiber cables or connectors. Never look directly into an un-
terminated cable or connector.
Note: This ONT uses a Class 1 laser device.
Danger! Personnel handling fiber optic cables must be trained for laser
safety.
Caution! Do not bend the fiber optic cable to a diameter smaller than 7.5
cm (3 inches). Doing so may damage the fiber or prevent the signal from
passing through properly.