CALOR DG3000WHB-7B Installation And Operation Instructions Manual

Manual is about: WATER RADIANT HEATING TOUCH SCREEN THERMOSTAT

Summary of DG3000WHB-7B

  • Page 1

    1 dg3000whb-7b water radiant heating touch screen thermostat manual dg3000whb-7b thermostat for radiant heating installation and operation instructions.

  • Page 2

    2 dg3000whb-7b is a 7 days programmable thermostat designed for water boiler and electric furnace application. This thermostat can be used for hot water radiant heating and electric cable heating system. Specification: power source …………………… 2 aa size 1.5v alkaline battery maximum resistive load……………...

  • Page 3

    3 dg3000whb-7b touch screen thermostat home screen description attach thermostat base to wall 1. Remove 2 screws from the bottom of thermostat. Gently pull the control panel straight off the base. Forcing or prying on the thermostat will cause damage to the unit. 2. Install two fresh “aa” alkaline b...

  • Page 4

    4 positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. 3. Connect wires beneath terminal screws on power supply module using appropriate wiring schematic. See figure 4 4. Push power base into wall. 5. Using two mounting screws mount the power base to the wal...

  • Page 5

    5 wiring diagram 1 2 3 230 v a c t 2 t 1 230 v a c 3 2 1 250v a c 8a 8a 8a 8a p um p or valve r elay 250v a c 8a 8a 8a 8a figure 4 check thermostat operation the unit will be controlled via air sensor in the thermostat and the thermostat will determine to activate/deactivate heating system by compar...

  • Page 6

    6 5) press done key to save the setting and exit configuration menu, hold reset key for 3 seconds display will flash 3 times and revert to factory default setting. The configuration menu chart summarizes the configuration options. An explanation of each option as follows: item current setting menu i...

  • Page 7

    7 select fa to start heating immediately when the set point is 1 ℃ above the room temperature. Select sl to start heating only when the set point is 3 ℃ above the room temperature. 6) select pump protection mode for hot water installations, it is recommended to activate the pump at least 15 second e...

  • Page 8

    8 resume schedule 3) press the cancel or sched key to cancel “hold until” and resume schedule note: once “hold until” time is reached, the thermostat shows “run schedule” on the screen to indicate that temporary hold has ended. Permanent hold permanent hold changes the temperature setting until perm...

  • Page 9

    9 2) press hold key again. Screen shows “hold until” one day 3) press up and down arrow key next to the day to change the number of days you desire thermostat to override the schedule 4) press up and down arrow key next to the temperature to set the desired temperature while away on holiday 5) to ca...

  • Page 10

    10 cleaning. 2) use damp cloth slightly moistened with water or house hold glass cleaner to clean the screen 3) repeat the above steps, as necessary important do not spray any type of liquid directly on the thermostat itself. If using household glass cleaner, spray cleaner on cloth. Then use a cloth...

  • Page 11

    11 planning your program the heating schedule below allow you to pencil in your own program times and temperatures. The thermostat comes configured for 7 day programming and can also be configured for 5+1+1 programming factory setting are listed on monday, saturday and sunday. If you are re-programm...

  • Page 12

    12 3) press wake key. Once pressed, wake flashes to show it is selected 4) press up and down keys to modify time and heat temperature from this screen. 5) press leave key and repeat step 4. 6) press return key and repeat 4 7) press sleep key and repeat 5. 8) press day key and repeat 2)-7) to program...