(N.C.) contactfor «partial stop»
- Input for safety devices such as photocells, sensitive edges and other EN 12978-compliant
devices. Gate leaves are stopped if in motion, with consequent setup of automatic closing.
Dip 8 OFF - 10 ON
If unused set DIP switch n.8 to ON
(N.C.) contactof «re-closing during opening»
- Input for safety devices such as photocells, sensitive edges and other EN 12978-compliant
devices. During the gate leaves closing phase, opening the contact causes movement inversion
until fully closed.
Dip 8 OFF - 10 OFF
Safety devices
(N.C.) contactfor «re-opening during closing»
- Input for safety devices such as photocells, sensitive
edges and other EN 12978-compliant devices. During the
gate leaves closing phase, opening the contact causes
movement inversion until fully opened.
If unused set DIP switch n.9 to ON
(N.C.) contactfor «re-opening during closing»
(N.C.) contactfor «re-closing during opening»
(N.C.) contactof «partial stop»
Or
Or