[LANGUAGE]
Default
[Italiano] / [English] / [Français] / [Deutsch] / [Español] / [Portugues euro]/[Portugues bras]
English
[FUNCTIONS]
Default
[Auto
Close]
[Disabled]
/
[Enabled]
[Enabled]
[Maint Action]
[Disabled] / [Enabled] / [Closing]
[Disabled]
[Obstruc
Detct]
[Disabled]
/
[Enabled]
[Disabled]
[Safety Test]
[Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ]
[Disabled]
[Preflashing]
[Disabled]
/
[Enabled]
[Disabled]
[Ram Jolt]
[Disabled] / [Closing] / [Opening] / [Open-Close]
[Disabled]
[Total
Stop]
[Disabled]
/
[Enabled]
[Enabled]
[CX input]
[Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8]
[C1]
[CY input]
[Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8]
[C3]
[CZ input]
[Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8]
[C2]
[Closing
thrust]
[Disabled]
/
[Enabled]
[Disabled]
[Lock]
[Disabled] / [Closing] / [Opening] / [Open-Close]
[Closing]
[LockType]
[Pulsed] / [Continuous]
[Pulsed]
[Config]
[Time Lmt Swtch] / [End Stop] / [Slow Down] / [Op LS-Cl Sl Dn] / [ENCODER]
[ENCODER]
[End
Stop] [N.C.
/
N.O.]
[N.C.]
[2-7
command]
[Open-Close]
/
[Opn
Stp
Clse]
[Open-Close]
[Light
E]
[Flashing
light]
/
[Courtesy]
/
[Cycle]
[Flashing
light]
[B1-B2
output]
[Bistable]
/
[Monostable]
[Monostable]
[IMP. TRAVEL]
Default
[Motor type]
[FROG-F4024E] / [FROG J] / [FROG-FL] / [AMICO] / [MYTO] / [AXO] / [FAST] / [FERNI]
[FROG-F4024E]
[Travel rate %]
[20%]
⇨ [100%]
[100%]
[Slow dwn speed]
[5%]
⇨ [80%]
[50%]
[Soft Start]
[Enabled] / [Disabled]
[Disabled]
[Amper.
Sens.]*
[Enabled]
/
[Disabled]
[Enabled]
[Travel sens]*
[-
◦+]
[Slow downtime]**
[0 s]
⇨ [30 s]
[20 s]
*This function does not appear if [ENCODER] from the [Config].
**This function only appears if [Slow Down]or [Op LS-Cl Sl Dn] from the [Config].
Menu map
Meaning of the menu items abbreviations
[Travel sens]
Gate Run Sensibility
[Partial open]
Partial
Opening
[Maint Action]
Maintained Action
[Auto Close]
Automatic Closing
[Config]
Configuration
[Assoc Function]
Associated Function
[Set Travel]
Set gate-leaf Travel
[Open Accel]
Opening Soft-Stop as a percentage
[CloseAccel]
Closing Soft-Stop as a percentage
[Opn Slw Dwn]
Opening Slow Down as a percentage
[Cls Slw Dwn]
Closing Slow Down as a percentage
[Change Code]
Mod.
name
[Start message]
Starting
message
[Soft Start]
Slowed-down Start
[Enc Slow Down]
Opening and closing slow-downs with ENCODER
[Obstruc Detct]
Obstruction Detection
[Delete user]
Remove
User
[Amper. Sens.]
Amperometric Sensitivity
[Travel sens]
Travel Sensitivity
[Slw Dwn sens]
Sensitivity of Slow Downs
[Closing thrust]
Closing thrust
[Ram jolt time]
Ram-jolt
Time
[Preflash time]
Preflashing Time
[Slow downtime]
Slow-down
Time
[Lock time]
Lock Time
[ACT]
Automatic
Closing
Time
[PartialACT] Partial Automatic Closing Time
[Slow dwn speed]
Slow-down
Speed
[Travel rate %]
Gate-leaf Travel Speed