Time settings menu
SET TIMES
[ACT]
[0 s]
⇨
[300 s]
The fi rst automatic-closing wait starts when the opening endstop point is reached and can be set to between 0 and 300 s. The automatic
closing does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power outage.
[Partial ACT]
[0 s]
⇨
[300 s]
Leaf waiting-time when open, after a partial close command. Once this time elapses, a closing maneuver is automatically performed. The
waiting time can be set to between 0 and 300 seconds.
[Cycle time]
[10 s]
⇨
[150 s]
Gearmotor working time during opening and closing. The working time can be set to between 10 and 150 seconds.
[Prefl ash time]
[1 s]
⇨
[60 s]
After an opening or closing command, the flashing light connected on 10-E, flashes between one and sixty seconds before starting the
maneuver.
[Lock time]
[1 s]
⇨
[5 s]
Intervention time for the electrolock to release after each opening command. The intervention time can be adjusted to between one second
and fi ve seconds.
[Ram jolt time]
[1 s]
⇨
[3 s]
The closing and opening jolt thrust-time of the geartmotors after each command. The thrust time can be set to between
one and three
seconds.
[Partial open]
[5 s]
⇨
[60 s]
Leaf opening time. The time can set between 5 s and 60 s.
[Courtesy Time]
[60 s]
⇨
[300 s]
Supplementary light. It stays on for the time needed during the gate's opening or closing maneuvers.
contact output [10-E3]. It is adjustable between 60 s and 300 s.
Users Menu
[USERS]
Users Menu
[USERS]
[Add User]
Entering up to 250 users and associating to each one a function of choice among those included. The entering must be done via transmit-
ter or other control device (
see ENTERING NEW USERS
).
[Change Name]
To change the number or name of users
[Change Code]
To modify the command code that is associated to a user
.
[Assoc Function]
[
2-7]
[Open]
[2-3P]
[B1-B2]
➡
Step-step command (open-close) or sequential command (open-stop-close-stop)
➡
Open only command
➡
Pedestrian or partial opening
➡
Contact B1-B2 output
[Delete user]
To remove a user. Confirm removal with ENTER.
[Delete ALL]
To remove all users. Confirm removal with ENTER.
[Open Accel]
[1%]
⇨
[15%]
Adjusting the soft-spot starting point as a percentage (from 1% to 15% of the complete travel) before the opening endstop point.
[Travel calibr]
Automatic calibration of the gate-leaf run (see the TRAVEL CALIBRATION paragraph)