1. From the [ENCODER]
menu, select [Travel
calibr]. Press ENTER to
confirm
2. Select [Confirm?
(Yes)] and press
ENTER to confirm.
3. The gate-leaf will close
until the final strike-point ...
4. ... then, the gate-
leaf, will open until the
final strike-point.
5. Once the procedure is
over, the display will show
[Travel calibr OK] for a few
seconds.
Travel calibration
⚠ Before calibrating the gate run, check that the maneuvering area is free from any obstruction and that there are both opening and
closing mechanical stops.
⚠ The mechanical end-stops are obligatory.
Important! During the calibration, all safety devices will be disabled except for the PARTIAL STOP one.
ERROR MESSAGE
Error messages appear on the display
.
[Encoder - ERROR], [Error!]
Broken encoder or wrong connection.
[Safety Test - ERROR]
Safety devices malfunctioning.
[End Stop - ERROR]
Malfunctioning endstop contacts
[Cycle time - ERROR]
Insufficient working time
[Safety - STOP], [C1], [C3], [C4], [C7] or [C8]
Malfunctioning safety devices or wrong connection
Memory roll
Memory Roll Card
For memorizing user and system configuration data, then using them on another control board.
After memorizing the data, it is best to remove the Memory Roll card while the control board is in operation.
Travel calibr
Close
Travel calibr
Travel calibr
Travel calibr
Open
Travel calibr
OK