Gate run setting menu
[Set Travel]
[Motor type]
[FROG-F4024E] / [FROG-J] / [FROG-FL] / [AMICO] / [MYTO] / [AXO] / [FAST] / [FERNI] / [ATI]
Setting the type of operator installed in the system.
[Travel rate %]
[50%]
⇨
[100%]
Adjusting the maneuvering speed, calculated as a percentage.
[Slow dwn speed]
[10%]
⇨
[50%]
Adjusting the slow-down speed, calculated as a percentage.
[Soft Start]
[Disabled] / [Enabled]
After each opening and closing command, the leaves start at slowed down speed for a few seconds.
[Amper. Sens.]
[Disabled] / [Enabled]
Obstruction detection sensibility.
This function does not appear if [Encoder] is set in the [Config] function.
When an obstruction is met the function intervenes in the following way:
- [Time Lmt Swtch]
it stops the gate leaves during a maneuver;
- [End Stop] it inverts the gate leaves during a maneuver;
- [Slow Down] it inverts the gate leaf movement during a maneuver and stop the movement during a slow down.
- [Lsop-Clos. Slw] it inverts the gate leaves during a maneuver and stops them only during the closing slow-down.
When the function is disabled, it stops the gate leaves when the maximum voltage threshold is exceeded.
[Travel sens]
[-
◦+]
Adjusting the Amperometric sensibility.
You need to turn on the [Amper. Sens.] in the [Set Travel].
[Slow down time]
[OFF]
⇨
[30 s]
Slow-down time of the gate leaves before every endstop. The time can be set to between zero and 30 s.
This function only appears if the [Slow Down] or [Lsop-Clos. Slw] from the [Config] function.
ENCODER menu
The [ENCODER] menu appears only when the [Config] in the [FUNCTIONS] menu.
[ENCODER] menu
[Sensitivity]
[Enabled] / [Disabled]
Obstruction detection sensibility.
[Travel sens]
[-
◦+]
Obstruction detection sensitivity during gate run (both opening and closing).
You need to turn on the [Sensitivity] in the [ENCODER] menu.
[Slw Dwn sens]
[-
◦+]
Obstruction detection sensitivity during slow-down (both opening and closing).
You need to turn on the [Sensitivity] in the [ENCODER] menu.
[Enc Slow Down]
[ON] / [OFF]
Activating the opening and closing slow-down starting points.
[Opn Slw Dwn]
[1%]
⇨
[40%]
Adjusting the starting slow-down point before the opening endstop.
The starting slow-down point is calculated as a percentage ( from 1% to 40% of the complete leaf-travel).
This function only appears if the [Enc Slow Down] in the [ENCODER] menu.
[Cls Slw Dwn
[1%]
⇨
[40%]
Adjusting the starting slow-down point before the closing endstop.
The starting slow-down point is calculated as a percentage ( from 1% to 40% of the complete leaf-travel).
This function only appears if the [Enc Slow Down] in the [ENCODER] menu.
[Close Accel]
[1%]
⇨
[15%]
Adjusting the soft-spot starting point calculated as a percentage (from 1% to 15% of the complete travel) before the closing endstop point.