Caminetti Montegrappa LIGHT 06 Installation, Use And Maintenance Manual - page 25
LIGHT series
ENGLISH
2.3.12
$MBEEJOH*OTUBMMBUJPO
8"3/*/( %VSJOH UIF GPMMPXJOH NPVOUJOH XPSL GPS
UIF DMBEEJOH UIF BQQMJBODF NVTU CF EJTDPOOFDUFE
GSPNFMFDUSJDBMQPXFS TXJUDIPò
*.1035"/5*GUIFDMBEEJOHXBTOPUNBOVGBDUVSFECZ
$BNJOFUUJ .POUFHSBQQB CVU JT JOTUFBE QSFQBSFE PO
TJUFCZUIFVTFSJUJTOFDFTTBSZUPQSPWJEFGPSBTMJUXJUI
BOBSFBPGOPMFTTUIBOTRDNVOEFSUIFCBTFPGUIF
DMBEEJOH JO PSEFS UP DSFBUF BO BJS JOMFU GPS QSPQFS
DPNCVTUJPO
Use a 17 mm spanner (wrench) to level the appliance on its
adjustable feet. Check the height of the hearth against the
cladding that is to be installed.
Begin the mounting of the cladding as per the instructions
supplied with our product, and always in full compliance with
the general guidelines speci
fi
ed under section 1.5.
Note that the appliance must never be sealed to the
cladding because the materials they are constructed from
have a di
ff
erent thermal expansion. Therefore, it is highly
recommended not to:
seal the cladding to the appliance;
1.
lay the weight of the cladding and of the
fl
are onto the
2.
appliance (we suggest the use of
fi
reresistant plasterboard for
a quickly-built, lighter
fl
are), and strictly avoid anchorage on
any parts of the appliance (see section 2.3.12).
The mantelshelf and any other component in wood or
combustible material must be out of the range of the heat
radiation area, or must be duly insulated and be placed at
least 1 cm away from the heater in order to let the air freely
fl
ow and prevent overheating.
2.3.13
'JOJTIJOHNBOUMFPSESZXBMMQBOFM
8"3/*/( 8IFO NPVOUJOH UIF öOJTIJOH NBOUMF PS
ESZXBMM QBOFM UIF BQQMJBODF NVTU CF EJTDPOOFDUFE
GSPNFMFDUSJDBMQPXFSTVQQMZ
We recommend the use of 1/2 - thick
fi
reproof
Cement board panels for building the
fi
nishing mantle or
drywall panel, supported by a skeleton of galvanised sections
duly anchored to the walls, ceiling and cladding mantelshelf.
5PQSFWFOUUIFUSBOTNJTTJPOPGUIFSNBMFYQBOTJPOJUJT
'03#*%%&/ UP BODIPS UIF öOJTIJOH NBOUMF PS UIF
ESZXBMMQBOFMUPBOZQBSUPGUIFBQQMJBODF
With these galvanised sections always prepare framework to
support and secure the warm air outlets to be positioned at
200÷210 cm o
ff
the
fl
oor.
If the ceiling is higher than 3 meters tall, install a third non-
closable air vent on the
fi
nishing mantle or drywall panel with
top edge approximately 30 cm from the ceiling: this vent,
whose louvers cannot be shut, ensures the natural emission
of the warm air stored inside the
fl
are.
*.1035"/5 3FGFS UP TFDUJPO GPS HVJEFMJOFT
SFHBSEJOH UIF DFJMJOH JOTVMBUJPO TVQQPSUFE BOE IFME
JOUP QMBDF CZ B QMBTUFSCPBSE QBOFM JOTUBMMFE
IPSJ[POUBMMZ
*OTUBMM UIF BMVNJOJVN øFYJCMF XBSN BJS EJTUSJCVUJPO
QJQFT CFGPSF DMPTJOH BOE DPNQMFUJOH UIF öOJTIJOH
NBOUMFPSUIFESZXBMMQBOFMXJUIöSFQSPPGQMBTUFSCPBSE
QBOFMT TFFTFDUJPO