FRONT PANEL CONTROLS
1.
Input Level Control
A dual concentric pot. arrangement feeding the mix bus where the back (outer) knob
adjusts GAIN and the front (inner) knob acts as a FADER. Level set by the GAIN control
is progressively attenuated by the FADER control by adjusting FADER anti-clockwise
from the fully open (clockwise) position. The FADER control, therefore, does not
contribute any more gain i.e. does not have (say) 10dB in hand.
2.
Pre-Fade Listen (PFL)
When selected, as indicated by orange iris, allows monitoring of this (and any other
channel currently in PFL mode) or engineer's (1 ENG.) headphones only. FADER
(see Section 1) is not operative and channels with PFL selected do not contribute to mix
bus or presenter's (2 PRES) headphones. Whenever PFL is selected for one or more
channels, the PPM meter automatically switches over to follow.
3.
High Pass or Rumble Filter
When selected, as indicated by orange iris, imposes a 6dB per octave high pass
filter on the channel. Turnover point (-1dB) is 120 Hz, -3dB point is 80 Hz
.
4.
Headphone Monitoring Select Switches
Mounted above the PPM are presenter's (PRES) and engineer's (ENG.) locking toggle
switches for monitoring
either mixer output (O/P) or control line input (CUE)
on their respective headphones. For engineer only, monitoring will be overridden by
PFL if selected.
5.
Talkback Routing (PTT)
CANFORD AUDIO PLC
CROWTHER ROAD WASHINGTON
TYNE & WEAR NE38 OBW, UK
admin (0191)418 1000
sales (0191)418 1122
fax (0191)418 1001
technical data