Cannon CANTERBURY Instruction Manual - page 8
8 | Cannon Canterbury Freestanding
Gas type
Natural or Propane gas,
as indicated on data plate
Gas consumption
26 MJ/hr input
Energy output
5.55 kW / 19.98 MJ/hr
Energy star rating
4.0 stars
Heater type
Gas space heater approved to
AS4553:2008
Operating pressure
Natural gas: 0.75 kPa (High)/
0.40 kPa (Low)
Propane gas: 2.65 kPa (High)/
1.1 kPa (Low).
Gas regulator
Integral part of controller
Min. inlet pressure
1.13 kPa (Nat Gas)
2.75 kPa (Propane)
Fan
3 speed
Ignition
Electronic direct spark
Power requirement
240V AC 10 Amp
switch socket
Power consumption
90 VA maximum
Optional accessories
• Clip on mesh safety guard
• Cathedral ceiling flue box
• Remote control thermostat
Flue kit (purchase
separately)
• 3 x 870mm lengths of
125mm ø painted flue
• 1 x 870mm length of
125mm ø plain flue
• 1 x ceiling ring
• 1 x flue spigot adaptor
• 1 x 125mm ø flue cowl
Overall dimensions
Refer to FIG 3
Please note: The data label is located on the left hand
side panel near the electronic control box.
CANTERBURY FREESTANDING SPECIFICATIONS
Cannon Canterbury Freestanding
FIG 3
Back View and Side View
650 mm
425 mm
723 mm