D.A.C.E DURASWING Installation And Owner's Manual

Summary of DURASWING

  • Page 1

    32 proud manufacturers & suppliers of: slide gate operators: • compact 300 • compact 500 • solo • condo • condo ac/dc swing gate operators: • duraswing garage door operators: • lazer sectional • lazer roll up • lazer vertical roll up • lazer tip up transmitter & receivers: • duratronic 2; 3; 4 & 6 b...

  • Page 2

    2 index introduction p3 legal requirements p3 specifications p3 general information p4 terms and definitions p4 general site layout p5 general operator layout p6 main pc board layout p7 electrical wiring p7 transformer (power supply) p8 mounting the operators p9 pedestal mount p10 inward swing p11 o...

  • Page 3

    30 connecting a solar panel 16 vac connector from transformer solar panel (min 20 watts) a regulator is not required when connecting a solar panel negative wire (-) positive wire (+) connect the solar panel wires to the 16 vac plug on the main pc board. (wire polarity is not important) solar panel s...

  • Page 4

    4 general information before installing these duraswing duraswing duraswing duraswing operators please read the following: there are a number of different methods of installing swing gate operators. The main factors that influ- ence the installation are as follows. • direction the gate/s swing: inwa...

  • Page 5

    28 the light /lock card (sa038) is designed to operate pillar lights or a magnetic or strike lock (lock used on single swing gates only). The pillar lights will remain on for four minutes after activation. So too a toggle switch can be connected to the light/lock card to switch the pillar lights as ...

  • Page 6

    6 general operator layout • inward swing gates use the long crank arm and the short conrod. • outward swing gates use the short crank arm and the long conrod. Do not tighten the crank arm until the closed direction has been established. See setting the limit switches duraswing operator crank arm bal...

  • Page 7

    26 used to stop the gate closing even if the vehicle is past the first set of beams but it may still be in the path of the closing gate. One set mounted on the gate posts and the other set mounted clear of the gate when the gate is in the open position. Wiring two sets of infrared safety beams (dura...

  • Page 8

    8 wiring from transformer to charger to connect the power supply, run a three core 1.5mm cable from the transformer to the main pc board in the master operator. The 16 vac output on the transformer must be connected to the 16 v input on the main pc board. The remaining wire must be connected from th...

  • Page 9

    24 connecting an external receiver when connecting any auxiliary equipment to the pc board ensure that all power is removed from the pc board. Pedestrian operation: a separate receiver, keyswitch or keypad must be connected to operate the gate in the pedestrian mode. The connection is done in the sa...

  • Page 10

    10 pedestal mount some points to remember: • measurements given for the mounting positions are guidelines only and should be used as such. • each installation will vary slightly. • to establish the correct position of the operators they should be held temporarily in position with the crank arms loos...

  • Page 11

    22 trg: this led will flash once when a trigger signal has been detected. If this led is on solid it indicates a possible fault in one of the trigger wires i.E. Intercom, receiver etc. Ped: this led is the same as the trigger led. It will indicate when a pedestrian trigger has been re- ceived. Loop:...

  • Page 12

    12 pedestal mount : outward swing all outward swing installations require short crank arms and long conrods. When outward swing gates are setup the operators will protrude into the driveway by 155mm on each side of the driveway. Any attempt to mount the operators in any other manner will cause opera...

  • Page 13

    20 pc board connections the following connectors are found on the main pc board: gnd:this connector is used as a common ground for all auxiliary equipment. (note: this is not earth) trig: this connector is the trigger input, this will open /close the gate. This is normally used for the receiver and ...

  • Page 14

    14 wall mount : inward swing all inward swing installations require long crank arms and short conrods. Use 12mm coach screws to secure the wall mount bracket. Use a minimum of 4 screws per wall mount gate in closed position gate in open position m in 4 2 0 m m 550 to 600mm from hinge ensure the cran...

  • Page 15

    18 8 when gate reaches the required open position, press the limit switch. This is made easier using a small flat screwdriver. The motor will stop. The limit switch can be released when the operators have stopped running. Press the test button on the pc board. The gates will now start opening. Lift ...

  • Page 16

    16 wiring the slave operator ensure that the cable is connected in the correct order. The cable must be connected from the pc board output labeled motor 2, to the limit switch diodes on the slave operator. The cable that is connected to the “a “output must be connected to the “a” input on the limit ...