D.A.C.E DURASWING Installation And Owner's Manual - page 8
8
WIRING FROM TRANSFORMER TO CHARGER
To connect the power supply, run a three core 1.5mm cable from the transformer to the main PC
board in the master operator. The 16 VAC output on the transformer must be connected to the 16 V
input on the main PC Board. The remaining wire must be connected from the E on the transformer to
the earth wire on the main PC Board. (see diagram). Alternatively the green earth wire must be con-
nected to an earth spike buried in the ground.
DO NOT USE COMMUNICATION CABLE FOR POWER!!
ELECTRICAL WIRING cont.
Place the cable in conduit a minimum of 300mm underground. The cable must be a minimum of
1.5mm three core cable. Ensure that the conduit is waterproof. Do not use communication type cable
for the power supply. Do not join cables underground.
Failure to wire the transformer
correctly will result in the
transformer being damaged.
DANGER HIGH VOLT-
AGE
220 V/AC IN-PUT
Transformer
Main PC Board
EARTH
16 VAC
Master Motor
Transformer (power supply)
16 volts output to PC Board
230 V Input
300 mm
Recommended distance = 50 m
25
WIRING ONE SET OF INFRARED SAFETY BEAMS (DuraOptics)
Note: although the installation of infrared safety beams does reduce the risk of the gate
striking an object while closing it does not guarantee against it.
Covers must be in place when beams
are active. Ensure that the correct cover
is placed onto each beam after setup
otherwise failure to do so may result in
faulty operation of the beams.
Ensure that number 2 dipswitch is set
“OFF” after connecting the beams.
Main PC Board