D.A.C.E DURASWING Installation And Owner's Manual - page 11
22
TRG: this LED will flash once when a trigger signal has been detected.
If this LED is on solid it indicates a possible fault in one of the trigger wires i.e. intercom, receiver etc.
PED: this LED is the same as the trigger LED. It will indicate when a pedestrian trigger has been re-
ceived.
LOOP: the connector is a dedicated input for slide operators and as such this LED is not active with
swing operators.
INF: this LED will switch off when a vehicle or pedestrian crosses the beam. If this LED is off continu-
ously it indicates a possible fault with the beams or the wires that connect the beams.
LED/STAT: this LED has a number of functions and it displays the following:
Flashing once every two seconds
= gate closed and AC power is connected.
Flashing once per second
= gate moving.
On solid (no flashing)
= gate open.
Off
= AC (mains) power disconnected.
12/24V: -this LED indicates that the 12 volt output is working. If this LED is off it indicates that the 3
amp resettable fuse has blown. In this case the power must be removed from the board and then re-
connected to the board. This will reset the fuse and normal operation can continue.
CHARGE: this LED is on when the AC power (mains) is connected. If this light is not on the battery
will continue to operate the gate but will eventually run flat and the gate will stop working. This LED
must be on at all times.
OPEN: this LED is on when the gate is opening or is in the open position.
CLOSE: this LED is on when the gate is closing or is in the closed position.
REV: this LED flashes when the motor operates (for slide gate operators only).
LOW BATT: this LED indicates that the battery is low or flat. This is a red LED and will flash continu-
ously until the battery is either recharged or changed.
LED FUNCTIONS
LED LAYOUT
CHARGE
TRIG
PED
LOOP
12/24V
INF
LED/STAT
OPEN
CLOSED
REV
LOW BATT
PLEASE NOTE:
LOOP input is used
for slide operators
ONLY!!
11
PEDESTAL MOUNT : INWARD SWING
The above diagram shows the correct position for the pedestal when installing an Inward Swing
pedestal mount motor.
Measurements A, B and C are all taken from the hinge of the gate.
When the gate is in the closed position the crank arm and conrod must extend away at the point of the
ball joint and form a straight line. Likewise,when the gate is in the open position the crank arm must
rotate back over the conrod and still form a straight line.
All INWARD swing installations require LONG crank arms and SHORT conrods.
AERIAL VIEW
GATE IN CLOSED POSITION
NOTE:
1.
The Crank Arm and Conrod must
both be in a straight line when the
gate is in the closed position.
2.
The gate must be set up in the
closed position.
ANGLE
A
B
C (±)
D(±)
60°
775
180
1200 1225
70°
500
180
885
985
80°
500
190
670
665
90°
500
400
665
780
100°
500
500
555
800
110°
500
600
485
880
A
B
C (approx)
D
(a
pp
ro
x)
SETTING GATE OPENING ANGLE