20
PC BOARD CONNECTIONS
The following connectors are found on the main PC Board:
GND:This connector is used as a common ground for all auxiliary equipment. (NOTE: THIS IS NOT
EARTH)
TRIG: This connector is the TRIGGER input, this will open /close the gate. This is normally used for
the receiver and /or intercom trigger (not for pedestrian mode)
PED: This connector is to accommodate a pedestrian trigger (optional). The opening distance is pre-
set and can not be changed. When the pedestrian trigger is used the gate will open partially and will
close automatically after 6 seconds.
LOOP:This is a dedicated input for slide operators and is NOT active with swing operators. Please
see page 29 for instructions for connecting a Loop Detector for a swing motor.
INF:This connector is used to connect infrared beams (optional). If the gate is closing and the beam is
interrupted the gate will stop and reopen. If the gate is opening and the beam is interrupted it will have
no effect on the gate. (see wiring diagrams for more details on wiring infrared beams)
LED/STAT: This connector can be used to connect a remote Light Emitting Diode (LED), an optional
facility. The anode (+) must be connected to the LED connector and the cathode (-) must be con-
nected to the GND connector. The remote LED will give the same indication as the STATUS LED on
the PC Board.
12/24V: This connector is used to supply power to auxiliary equipment used i.e intercom; receiver;
infrared beams etc. This output has a resettable fuse for protection. (see wiring diagrams for more
details on wiring auxiliary equipment ). This is not to be used to power up a Magnetic Lock or
Strike Lock.
Ensure that all power is disconnected from the P.C.BOARD before any connections are made.
Failing to do this will result in electrical shorts and major damage may occur to the PC BOARD.
CONNECTOR BLOCK ON MAIN PC BOARD
GND
PED
LED/
STAT
INF
LOOP
12/
24V
TRIG
PLEASE NOTE: LOOP input is used for
slide operators ONLY!!
13
PEDESTAL MOUNT : PANHANDLE INWARD SWING
All INWARD swing installations require LONG crank arms and SHORT conrods.
A
ANGLE
A
B
C
D
90°
350
130
500
470
90°
700
140
557
668
SETTING GATE OPENING ANGLE
NB: All measurements are given as guidelines. Each
installation will vary marginally.
PLEASE NOTE: IN THE EVENT OF OPERATOR FAILURE (LOW BATTERY etc.) AND
THE CONROD IS DISCONNECTED FROM THE GATE, THE GATE WILL ONLY OPEN
UNTIL IT FOULS WITH THE CRANCK ARM.
GATE IN CLOSED POSITION
AERIAL VIEW
NOTE:
1.
The Crank Arm and Conrod must both be
in a straight line when the gate is in the
closed position.
2.
The gate must be set up in the closed
position.
C
MIN 250
Centre of the hinge to the
centre of the pedestal.