Dacor Epicure EGR30 Installation Instructions Manual - Nstallation
i
nsTallaTion
s
peCifiCaTions
C
abineT
& C
ounTeRTop
p
RepaRaTion
A
A
25"
(635mm)
8"
(203mm)
12"
(305mm)
30" (762mm)
Minimum
18" (457mm)
Minumim
10" (254mm) Min.
to combustible side
walls above the range
(both sides)
Top of
finished
counter
Vertical
non-combustible
surface
Hood
13"
(330mm)
Maximum
B
ERD36 & ERD48
Model Number
“A”
“B”
ERD30
36” (914mm)
Recommended
30” (762mm) Minimum
30 1/16” (764mm)
EGR30
ERD36
42” (1067mm)
Recommended
36” (914mm) Minimum
36 1/16” (203mm)
ERDE36
ERD48
54” (1372mm)
Recommended
48” (1219mm) Minimum
48 1/8” (1222mm)
ERDE48
ERD60
66” (1676mm)
Recommended
60” (1542mm) Minimum
60 1/8” (1572mm)
Cutout Dimensions
Both the gas supply piping and shut-off valve, and the electrical
junction box/receptacle must be located so they do not interfere
with the range when it is installed. In addition, the junction box
must be located so the range can be removed for service when
the conduit supplied with the unit is attached to the junction box.
Do not lengthen the conduit or wiring provided with the range.
All dimensions shown are based on standard American cabinets
36 inches (914mm) high at the finished countertop by 24 inches
(610mm) deep, with a 25 inch (635mm) overall countertop depth.
When installing the range into nonstandard cabinets, minimum
clearances shown in the diagrams on page 3 must be maintained.
Carefully check the location where the range is to be installed. For
best performance, the range should be placed away from drafts
that may be caused by doors, windows and HVAC outlets.
NOTES:
1.
If cabinet storage space is to be provided directly
above the range, the risk of personal injury may
be reduced by installing a ventilating hood that
projects horizontally a minimum of 5 inches
beyond the face of the cabinets.
2. The range may be installed flush to the rear wall.
We recommend installing a non-combustible
material on the rear wall above the range and up
to the vent hood. It is not necessary to install non-
combustible materials behind the range below the
countertop height.
3. The minimum distance from the sides of the range
above the countertop to combustible side walls
must be at least 10 inches.
NOTE:
On 36” and 48” models, install either the 3”, 9” or 24”
Backguard on the Range prior to installing the Range
into the cabinet cutout.
NOTE:
Utilities may be located: In the lower left corner of the
adjacent right cabinet. (Recommended)
IMPORTANT:
Contact your local building department to verify
compliance with local code interpretation.