    Installation instructions remote blowers models: remp3, remp16 part no. 65265 rev. G suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a dacor ® hood assembly or dacor raised vent must be purchased separately. See the hood or raised ve...

  • Page 2

    Installation instructions .................................................... 6 parts list .......................................................................... 6 installation ........................................................................ 6 verifying proper operation ...................

  • Page 3

    1 important information about safety instructions the • important safety instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or oper- ating this or any other appliance. A...

  • Page 4

    2 important safety instructions do not install or operate this unit if it has been dam- • aged, dropped, has damaged electrical wiring or is not working properly. If the product is damaged when received, immediately contact the dealer or builder. Install or locate this appliance only in accordance •...

  • Page 5

    3 product dimensions product specifications 17 3/8" (441mm) 19" (483mm) 24 1/4" (616mm) 3 5/8" (92mm) 9 1/4" (235mm) mounting flange 25 1/2" (648mm) 7 1/2" (191mm) 9 1/2" (241mm) discharge intake collar power supply conduit hole c l c l c l c l 26" (660mm) 32 1/4" (819mm) 3 5/8" (92mm) 12 1/4" (311m...

  • Page 6

    4 installation planning system layout warning to avoid the risk of fire due to the unit overheating: do not • install this blower with a hood or raised vent that has an internal blower. Do not • install more than one blower to increase the length of the duct run. Even small differences between blowe...

  • Page 7

    5 the blower must also be mounted vertically or at a • pitch of 2:12 or greater. If the pitch of the mounting sur- face is less than 2:12, construct a roof curb to mount the blower. See installation preparation for exact dimensions. When mounted in a exposed location shield it to pre- • vent the acc...

  • Page 8

    6 warning if the electrical service provided does not meet the • power requirements for the hood/raised vent and the blower combined, do not continue with the instal- lation. Contact a licensed electrician to correct the situation before continuing. Failure to connect the wiring as specified may res...

  • Page 9

    7 electrical installation run the wiring used to supply power from the installed 7. Raised vent or hood to the blower parallel to the duct work. Make sure that power to the raised vent or hood is 8. Disconnected or turned off at the circuit breaker or fuse box. With the ul certified strain relief at...

  • Page 10

    8 technical data remp series blower ratings model number nominal rating* actual rating* remp3 600 cfm 620.5 cfm remp16 1000 cfm 994.8 cfm airflow cfm (cubic feet/minute) static pressure - inches of water 0 1.0 2.0 3.0 4.0 5.0 100 200 300 400 500 600 700 remp3 blower performance airflow cfm (cubic fe...