• Responsibility will not be accepted due to inconveniences to arise from the
use of different brands of thermostat.
• Room thermostat connection is being seen on the electric circuit scheme.
(Page 5, Figure 1)
lnformation Required for Secure and Economic Use of Vour Combi Boiler
• The isolation of your building is extremely important. As heat loss is minimized at houses
whose walls are isolated, on which jacketing is made and with double glazing, significant
energy saving is ensured.
• The use of thermostatic valves on your radiators enables the room temperatures to
remain constant and fuel saving.
• Cutting down the radiator valves at rooms which will not be used for a long period and
keeping their doors closed decreases fuel consumption.
• lf you use your combi boiler with room thermostat, less fuel consumption is achieved by
keeping the temperature of space at the set level.
• As closing the tops and fronts of radiators with furniture ete. negatively affects hot air
circulation, it prevents heating up of the environment and causes the increase of fuel
consumption.
• lf you will leave your device in operating state at late hours, keeping the water temperature of
central heating circuit low will enable saving.
• Of you feel that the room temperature is high, the radiator valves should be cut down
instead of opening the windows.
START-UPAND USAGE
Final Controls and Operations Required to be Performed Before Start-Up
Bilgi
• As the result of determining the location of assembly of the combi
boiler in accordance with the standards of TSE and authorized gas
company and hanging of it, and as the result of completion of
assembly by completing the funnel, electric, water and gas
connections, the following controls and operations should be
performed by authorized installer vendor.
1} Filling water to the combi boiler and central heating system
- First the electric connection of the combi boiler is made.
- AII the radiator valves are opened.
- The valves of central heating outlet-return lines of the combi boiler should be open. Check it.
- During the performance of water filling operation, the system's water pressure value is followed-up from the
pressure indicator on the LCD display of your device. The pressure value on LCD display should be in between 1-
1.5 bar. When it is reached to this value, close the filling valve.
21