Easy-Kleen AS152E Alternate Spec Owner's manual - General Maintenance
1
2
Cold Water Electric • Rev.
17/10/2016
GENERAL MAINTENANCE
Water Condition
Use a softener on your water system if local water is known to be high in mineral content. The
advantages of soft water are very beneficial: prevents scale buildup in heater coil, cleans better
with considerably less detergent, prevents streaking on painted surfaces and glass when rinsing.
MAINTENANCE CHECKLIST
Daily
1.
Check pump oil for proper level and adjust accordingly.
2.
Examine the quality of the oil.
3.
Check pump for oil and/or water leaks.
4.
Inspect and clean inlet filters.
Weekly
1.
Examine all fittings, components
and
connections for damages, loose
parts, or leaks.
– Replace accordingly—
2. Check for water leaks
3. Check thermostat occasionally
Recommendation for Oil Changes and Component Replacement
1. Change the oil in the pump after the first 50 hours and every 500 hours after the initial
oil change. Use SAE 30 W Non-Detergent for GP Pumps and Hydraulic 68 for EK
Pumps.
2. Change all other components on the pump as needed.
Monthly
1. Check fuel filter