Eaton BladeUPS none Installation Manual

Other manuals for BladeUPS none: User Manual, User Manual, User Manual, User Manual, User Manual, User Manual
Manual is about: For use with Eaton BladeUPS 5 kVA to 60 kVA (N+1) systems

Summary of BladeUPS none

  • Page 1

    Powerware series eaton bladeups bar installation guide ® ®.

  • Page 2: Special Symbols

    Special symbols the following are examples of symbols used on the ups or accessories to alert you to important information: risk of electric shock - observe the warning associated with the risk of electric shock symbol. Caution: refer to operator's manual - refer to your operator's manual for additi...

  • Page 3

    Eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality i table of contents 1 introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 4

    Table of contents eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality ii.

  • Page 5

    Eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 1 chapter 1 introduction paralleled eaton bladeups ® uninterruptible power systems (upss) use the eaton bladeups bar to provide the required input and output connections. The bladeups bar installs in an industry stand...

  • Page 6: Safety Warnings

    Introduction eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 2 safety warnings important safety instructions save these instructions this manual contains important instructions that you should follow during installation and maintenance of the bladeups bar. Please r...

  • Page 7: Aufbewaren

    Introduction eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 3 wichtige sicherheitsanweisungen aufbewaren dieses handbuch enthält wichtige hinweise, welche sie bei der installation und wartung des bladeups bar beachten sollten. Bitte lesen sie alle anweisungen des ...

  • Page 8: Guarde Estas Instrucciones

    Introduction eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 4 instrucciones de seguridad importantes guarde estas instrucciones este manual contiene instrucciones importantes que debe seguir durante la instalación y el funcionamiento del bladeups bar. Por favor, l...

  • Page 9: Inspecting The Equipment

    Eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 5 chapter 2 installation this section explains: s equipment inspection s bladeups bar setup and installation inspecting the equipment if any equipment has been damaged during shipment, keep the shipping cartons and pa...

  • Page 10: Bladeups Bar Installation

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 6 checking the package contents verify that the following items are included in the package: s one of the following bladeups bars: bladeups bar 4-high. A four-socket bar with (1) attached terminal block a...

  • Page 11

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 7 bladeups bar installation (bottom entry wireway) to install the bladeups bar in a bottom entry rack: 1. Remove the access cover and terminal block housing from the wireway housing (see figure 2). Retain...

  • Page 12

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 8 4. Install an m6 hex nut onto each of the three wireway studs to secure the wireway to the rear of the rack. Install the first stud in the fourth hole location from the bottom. Do not tighten the nuts. ...

  • Page 13

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 9 9. Place the ferrite assembly on the floor of the wireway and secure with the supplied tie wrap. Loop the tie wrap through both attachment sites on the wireway floor and through the ferrite assembly. Se...

  • Page 14

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 10 12. Secure the bar to the wireway with three m6 12 hex bolts. Install the bolts from the front of the rack. See figure 5. Torque the bolts to 5.1 ± 0.8 nm (45 ± 7 lb in). 13. Reinstall the terminal blo...

  • Page 15

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 11 14. Secure the terminal block assembly bracket to the rack with three m6 12 hex bolts. Install the bolts from the rear of the rack. Use a large screwdriver or crowbar to lift the bar in place to align ...

  • Page 16

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 12 15. Bladeups bar 4-high. Install two m6 12 hex bolts in each of the bar's two mounting brackets, securing the length of the bar to the rack. See figure 6. Torque the bolts to 5.1 ± 0.8 nm (45 ± 7 lb in...

  • Page 17

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 13 note loosening the mounting brackets slightly may allow easier alignment to the vertical rail of the rack. Retighten the mounting brackets when alignment is complete. 18. Using two m6 12 hex bolts, sec...

  • Page 18

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 14 20. Using five m4 8 pan-head screws, install the wireway access cover. See figure 8. Torque the screws to 1.7 ± 0.2 nm (15 ± 2 lb in). M4 8 pan-head screws (5 places) wireway access cover rear of rack ...

  • Page 19

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 15 22. Using four m5 16 hex bolts and four m5 cage nuts, secure the front cover mounting panel to the front of the rack. Ensure that the bent edge of the panel is at the top. See figure 10. Install the lo...

  • Page 20

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 16 23. Snap the two front covers into place, as shown in figure 11. Front covers (2 pieces) front of rack figure 11. Front cover installation.

  • Page 21

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 17 bladeups bar installation (top entry wireway) to install the bladeups bar in a top entry rack: 1. Remove the access cover and terminal block housing from the wireway housing (see figure 12). Retain the...

  • Page 22

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 18 5. Loosen the three adjustment screws on each side of the wireway housing and adjust the side brackets for the depth of the rack. Do not retighten the screws. 6. Install six m6 12 pan-head screws and m...

  • Page 23

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 19 11. Place the bar in the rack as shown in figure 14. Note the bar can rest on a support until secured in place. After complete installation, the bar will be secured to the rack and wireway as shown in ...

  • Page 24

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 20 12. Secure the bar to the wireway with three m6 12 hex bolts. Install the bolts from the front of the rack. See figure 15. Torque the bolts to 5.1 ± 0.8 nm (45 ± 7 lb in). 13. Reinstall the terminal bl...

  • Page 25

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 21 15. Bladeups bar 4-high. Install two m6 12 hex bolts in each of the bar's two mounting brackets, securing the length of the bar to the rack. See figure 16. Torque the bolts to 5.1 ± 0.8 nm (45 ± 7 lb i...

  • Page 26

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 22 note loosening the mounting brackets slightly may allow easier alignment to the vertical rail of the rack. Retighten the mounting brackets when alignment is complete. 18. Using two m6 12 hex bolts, sec...

  • Page 27

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 23 20. Using five m4 8 pan-head screws, install the wireway access cover. See figure 18. Torque the screws to 1.7 ± 0.2 nm (15 ± 2 lb in). M4 8 pan-head screws (5 places) wireway access cover rear of rack...

  • Page 28

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 24 22. Using four m5 16 hex bolts and four m5 cage nuts, secure the front cover mounting panel to the front of the rack. Ensure that the bent edge of the panel is at the top. See figure 20. Install the up...

  • Page 29

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 25 23. Snap the two front covers into place, as shown in figure 11. Front covers (2 pieces) front of rack figure 21. Front cover installation.

  • Page 30

    Installation eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 26.

  • Page 31

    Eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 27 chapter 3 specifications this section provides the following specifications: table 1. Bladeups bar bladeups bar 4-high bladeups bar 6-high dimensions (wxdxh) 152 145 1296 mm (6.0 ” x 5.7 ” 51.0”) 152 145 1829 mm (6...

  • Page 32

    Specifications eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 28.

  • Page 33

    Eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 29 chapter 4 service and support if you have any questions or problems with the bladeups bar, call your local distributor or the help desk at one of the following telephone numbers and ask for a ups technical represen...

  • Page 34

    Service and support eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 30 if repair is required, you will be given a returned material authorization (rma) number. This number must appear on the outside of the package and on the bill of lading (if applicable). Use the ...

  • Page 35: Limited Warranty

    Eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 31 chapter 5 warranty limited warranty eaton ® ups model: bladeups ® (global) warrantor: the warrantor for the limited warranties set forth herein is eaton corporation, an ohio corporation (“eaton”). Limited warranty:...

  • Page 36

    Warranty eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 32 what this limited warranty does not cover: this warranty does not cover any defects or damages caused by: (a) failure to properly store the product before installation, including the charge of batteries no...

  • Page 37

    Warranty eaton bladeups bar installation guide s 164201723 rev 2 www.Eaton.Com/powerquality 33 other limitations: eaton’s obligations under this warranty are expressly conditioned upon receipt by eaton of all payments due from end-user (including interest charges, if any). During such time as eaton ...